Run‐time motion and first‐order shim control by expanded servo navigation
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30262 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Malte Riedel und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Switzerland. Hauptthemen laut MEDLINE: Phantoms, Imaging, Brain, Magnetic Resonance Imaging, Algorithms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Horizon 2020 Framework Programme.
Abstract (Originalsprache)
Purpose
To provide a navigator‐based run‐time motion and first‐order field correction for three‐dimensional human brain imaging with high precision, minimal calibration and acquisition, and fast processing.
Methods
A complex‐valued linear perturbation model with feedback control is extended to estimate and correct for gradient shim fields using orbital navigators (2.3 ms). Two approaches for sensitizing the model to gradient fields are presented, one based on finite differences with three additional navigators, and another projection‐based approximation requiring no additional navigators. A mechanism for noise decorrelation of the matrix and the data is proposed and evaluated to reduce unwanted parameter biases.
Results
The rigid motion and first‐order field control achieves robust motion and gradient shim corrections improving image quality in a series of phantom and in vivo experiments with varying field conditions. In phantom scans, magnet drifts, forced gradient field perturbations and field distortions from shifts of a second bottle phantom are successfully corrected. Field estimates of the magnet drifts are in good agreement with concurrent field probe measurements. For in vivo scans, the proposed method mitigates field variations from torso motions while being robust to head motion. In vivo gradient field precisions were along with single‐digit micrometer and millidegree rigid precisions.
Conclusion
The navigator‐based method achieves accurate, high‐precision run‐time motion and field corrections with low sequence impact and calibration requirements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Switzerland.
ORCID-Profile: Malte Riedel, Thomas Ulrich, Klaas P Pruessmann
Förderung
- Horizon 2020 Framework Programme
Zitieren
APA
Riedel, M., Ulrich, T., & Pruessmann, K. P. (2025). Run‐time motion and first‐order shim control by expanded servo navigation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30262
Vancouver
Riedel M, Ulrich T, Pruessmann KP. Run‐time motion and first‐order shim control by expanded servo navigation. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30262
BibTeX
@article{Riedel2025,
author = {Riedel, Malte and Ulrich, Thomas and Pruessmann, Klaas P},
title = {Run‐time motion and first‐order shim control by expanded servo navigation},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30262}
}
EUVIMED