EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Three‐dimensional radial echo‐planar spectroscopic imaging for hyperpolarized 13 C MRSI in vivo

Marcel Awenius iD, Helen Abeln, Melanie Müller, Vanessa L Franke iD, Gino Rincon, Christin Glowa, Michaela Schmitt, Renate Bangert, Dominik Ludwig, Andreas B Schmidt, Tristan A Kuder, Mark E Ladd und 3 weitere

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30258 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Marcel Awenius und 14 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Phantoms, Imaging, Imaging, Three-Dimensional. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: German Cancer Consortium, Deutschen Konsortium für Translationale Krebsforschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To demonstrate the feasibility of 3D echo‐planar spectroscopic imaging (EPSI) technique with rapid volumetric radial k‐space sampling for hyperpolarized (HP) 13 C magnetic resonance spectroscopic imaging (MRSI) in vivo.

Methods

A radial EPSI (rEPSI) was implemented on a 3 T clinical PET/MR system. To enable volumetric coverage, the sinusoidal shaped readout gradients per k‐t‐spoke were rotated along the three spatial dimensions in a golden‐angle like manner. A distance‐weighted, density‐compensated gridding reconstruction was used, also in cases with undersampling of spokes in k‐space. Measurements without and with HP 13 C‐labeled substances were performed in phantoms and rats using a double‐resonant 13 C/ 1 H volume resonator with 72 mm inner diameter.

Results

Phantom measurements demonstrated the feasibility of the implemented rEPSI sequence, as well as the robustness to undersampling in k‐space up to a factor of 5 without advanced reconstruction techniques. Applied to measurements with HP [1‐ 13 C]pyruvate in a tumor‐bearing rat, we obtained well‐resolved MRSI datasets with a large matrix size of 12 3 voxels covering the whole imaging FOV of (180 mm) 3 within 6.3 s, enabling to observe metabolism in dynamic acquisitions.

Conclusion

After further optimization, the proposed rEPSI method may be useful in applications of HP 13 C‐tracers where unknown or varying metabolite resonances are expected, and the acquisition of dynamic, volumetric MRSI datasets with an adequate temporal resolution is a challenge.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingPhantoms, ImagingImaging, Three-DimensionalAnimalsRatsAlgorithmsPyruvic AcidCarbon IsotopesCarbon-13 Magnetic Resonance SpectroscopyReproducibility of ResultsFeasibility Studies

Stichwörter der Autor:innen

13C MRSIdynamic nuclear polarizationecho‐planarhyperpolarizationradial

Substanzen

Pyruvic AcidCarbon Isotopes

Autor:innen und Institutionen

  • Division of Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany.
  • Max-Planck-Institute for Nuclear Physics, Heidelberg, Germany.
  • Faculty of Chemistry and Earth Sciences, University of Heidelberg, Heidelberg, Germany.
  • German Cancer Consortium (DKTK), core center Heidelberg and German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.

ORCID-Profile: Marcel Awenius, Vanessa L Franke, Andreas Korzowski

Förderung

  • German Cancer Consortium
  • Deutschen Konsortium für Translationale Krebsforschung

Zitieren

APA

Awenius, M., Abeln, H., Müller, M., Franke, V. L., Rincon, G., Glowa, C., Schmitt, M., Bangert, R., Ludwig, D., Schmidt, A. B., Kuder, T. A., Ladd, M. E., Bachert, P., Biegger, P., & Korzowski, A. (2025). Three‐dimensional radial echo‐planar spectroscopic imaging for hyperpolarized 13 C MRSI in vivo. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30258

Vancouver

Awenius M, Abeln H, Müller M, Franke VL, Rincon G, Glowa C, et al. Three‐dimensional radial echo‐planar spectroscopic imaging for hyperpolarized 13 C MRSI in vivo. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30258

BibTeX
@article{Awenius2025,
  author = {Awenius, Marcel and Abeln, Helen and Müller, Melanie and Franke, Vanessa L and Rincon, Gino and Glowa, Christin and Schmitt, Michaela and Bangert, Renate and Ludwig, Dominik and Schmidt, Andreas B and Kuder, Tristan A and Ladd, Mark E and Bachert, Peter and Biegger, Philipp and Korzowski, Andreas},
  title = {Three‐dimensional radial echo‐planar spectroscopic imaging for hyperpolarized 13 C MRSI in vivo},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30258}
}
Kostenlos starten →