EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Spectrally selective bSSFP using off‐resonant RF excitations permits high spatiotemporal resolution 3D metabolic imaging of hyperpolarized [ 1‐ 13 C ]Pyruvate‐to‐[ 1‐ 13 C ]lactate conversion

Jason G Skinner, Geoffrey J Topping, Luca Nagel, Irina Heid, Christian Hundshammer, Martin Grashei, Frits H A van Heijster, Rickmer Braren, Franz Schilling iD

Magnetic Resonance in Medicine · 2023

DOI: 10.1002/mrm.29676 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Jason G Skinner und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany. Hauptthemen laut MEDLINE: Pyruvic Acid, Lactic Acid. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, European Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a high spatiotemporal resolution 3D dynamic pulse sequence for preclinical imaging of hyperpolarized [1‐ 13 C]pyruvate‐to‐[1‐ 13 C]lactate metabolism at 7T.

Methods

A standard 3D balanced SSFP (bSSFP) sequence was modified to enable alternating‐frequency excitations. RF pulses with 2.33 ms duration and 900 Hz FWHM were placed off‐resonance of the target metabolites, [1‐ 13 C]pyruvate (by approximately −245 Hz) and [1‐ 13 C]lactate (by approximately 735 Hz), to selectively excite those resonances. Relatively broad bandwidth (compared to those metabolites' chemical shift offset) permits a short TR of 6.29 ms, enabling higher spatiotemporal resolution. Bloch equation simulations of the bSSFP response profile guided the sequence parameter selection to minimize spectral contamination between metabolites and preserve magnetization over time.

Results

Bloch equation simulations, phantom studies, and in vivo studies demonstrated that the two target resonances could be cleanly imaged without substantial bSSFP banding artifacts and with little spectral contamination between lactate and pyruvate and from pyruvate hydrate. High spatiotemporal resolution 3D images were acquired of in vivo pyruvate‐lactate metabolism in healthy wild‐type and endogenous pancreatic tumor‐bearing mice, with 1.212 s acquisition time per single‐metabolite image and (1.75 mm) 3 isotropic voxels with full mouse abdomen 56 × 28 × 21 mm 3 FOV and fully‐sampled k‐space. Kidney and tumor lactate/pyruvate ratios of two consecutive measurements in one animal, 1 h apart, were consistent.

Conclusion

Spectrally selective bSSFP using off‐resonant RF excitations can provide high spatio‐temporal resolution 3D dynamic images of pyruvate‐lactate metabolic conversion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pyruvic AcidLactic AcidMiceAnimalsMagnetic Resonance ImagingImaging, Three-DimensionalPhantoms, ImagingCarbon Isotopes

Stichwörter der Autor:innen

bSSFPhyperpolarized 13Clactatemetabolismpyruvatetumor heterogeneity

Substanzen

Pyruvic AcidLactic AcidCarbon Isotopes

Autor:innen und Institutionen

  • Department of Nuclear Medicine, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • German Cancer Consortium (DKTK), Partner Site Munich and German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • Munich Institute of Biomedical Engineering, Technical University of Munich, Munich, Germany.

ORCID-Profile: Franz Schilling

Förderung

  • Deutsche Forschungsgemeinschaft
  • European Commission

Zitieren

APA

Skinner, J. G., Topping, G. J., Nagel, L., Heid, I., Hundshammer, C., Grashei, M., van Heijster, F. H. A., Braren, R., & Schilling, F. (2023). Spectrally selective bSSFP using off‐resonant RF excitations permits high spatiotemporal resolution 3D metabolic imaging of hyperpolarized [ 1‐ 13 C ]Pyruvate‐to‐[ 1‐ 13 C ]lactate conversion. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29676

Vancouver

Skinner JG, Topping GJ, Nagel L, Heid I, Hundshammer C, Grashei M, et al. Spectrally selective bSSFP using off‐resonant RF excitations permits high spatiotemporal resolution 3D metabolic imaging of hyperpolarized [ 1‐ 13 C ]Pyruvate‐to‐[ 1‐ 13 C ]lactate conversion. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29676

BibTeX
@article{Skinner2023,
  author = {Skinner, Jason G and Topping, Geoffrey J and Nagel, Luca and Heid, Irina and Hundshammer, Christian and Grashei, Martin and van Heijster, Frits H A and Braren, Rickmer and Schilling, Franz},
  title = {Spectrally selective bSSFP using off‐resonant RF excitations permits high spatiotemporal resolution 3D metabolic imaging of hyperpolarized [ 1‐ 13 C ]Pyruvate‐to‐[ 1‐ 13 C ]lactate conversion},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29676}
}
Kostenlos starten →