Radial multi‐echo bSSFP and IDEAL chemical shift separation in k‐space for high‐speed 3D hyperpolarized 13 C metabolic MRI
Magnetic Resonance in Medicine · 2025
DOI: 10.1002/mrm.30614 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Zirun Wang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Medical Physics, Department of Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Imaging, Three-Dimensional. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: B.E.S.T. Fluidsysteme GmbH I Swagelok Stuttgart, Twinning of Magnetic Resonance Imaging Research Institutes, MRITwins, Deutschen Konsortium für Translationale Krebsforschung.
Abstract (Originalsprache)
Purpose
Hyperpolarized (HP) carbon‐13 ( 13 C) MRSI provides real‐time information about metabolic processes but lacks high temporal and spatial resolution. This study introduces a multi‐echo–balanced steady‐state free precession (ME‐bSSFP) method with a 3D radial readout trajectory in a spiral phyllotaxis pattern as a method for non‐Cartesian HP 13 C MRSI that allows for flexible reconstruction with high spatiotemporal resolution.
Methods
The approach uses ME‐bSSFP with iterative decomposition of echo asymmetry and least‐squares estimation (IDEAL) for separating 13 C metabolite signals. The method was evaluated using thermally polarized 13 C‐enriched phantoms and in vivo experiments in healthy rats injected with HP [1‐ 13 C]pyruvate.
Results
The method successfully acquired and separated thermally polarized and HP 13 C metabolite signals, demonstrating its versatility and effectiveness. This approach allows for the extraction of high temporal‐ or high spatial‐resolution 3D MRI from the same measurement. In vivo, dynamic HP metabolite intensities were extracted at a temporal resolution of 16 ms, and dynamic 3D metabolite images were generated with an isotropic FOV of 356 mm and a spatial resolution of 5.56 mm in 4.8 s.
Conclusion
The proposed radial ME‐bSSFP method with iterative decomposition of echo asymmetry and least‐squares estimation decomposition provides a flexible, efficient, and robust approach for HP 13 C MRSI. It opens new possibilities for monitoring metabolic processes with unprecedented temporal resolution, generating dynamic 3D metabolite maps, and applying rapid acquisition and undersampling schemes. The method's ability to optimize imaging temporal resolution and facilitate kinetic modeling paves the way for innovative applications in dynamic HP metabolic MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Medical Physics, Department of Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
- Technical University of Munich, School of Medicine and Health, Department of Nuclear Medicine, TUM University Hospital, Munich, Germany.
- German Cancer Research Center (DKFZ), Heidelberg, Germany.
- Faculty of Physics and Astronomy, University of Heidelberg, Heidelberg, Germany.
- German Cancer Consortium (DKTK), partner site Munich and German Cancer Research Center (DKFZ), Heidelberg, Germany.
- Munich Institute of Biomedical Engineering, Technical University of Munich, Garching, Germany.
ORCID-Profile: Zirun Wang, Johannes Fischer, Ali C Özen, Michael Bock, Franz Schilling, Christoph A Müller
Förderung
- B.E.S.T. Fluidsysteme GmbH I Swagelok Stuttgart
- Twinning of Magnetic Resonance Imaging Research Institutes, MRITwins
- Deutschen Konsortium für Translationale Krebsforschung
- Research Commission of the University Medical Center Freiburg
- Deutsche Forschungsgemeinschaft
- Bundesministerium für Bildung und Forschung, "QuE-MRT", contract number
- Bundesministerium für Bildung und Forschung
Zitieren
APA
Wang, Z., Grashei, M., Fischer, J., Sühnel, S., Setzer, N., Awenius, M., Korzowski, A., Özen, A. C., Zaitsev, M., Bock, M., Schilling, F., Schmidt, A. B., & Müller, C. A. (2025). Radial multi‐echo bSSFP and IDEAL chemical shift separation in k‐space for high‐speed 3D hyperpolarized 13 C metabolic MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30614
Vancouver
Wang Z, Grashei M, Fischer J, Sühnel S, Setzer N, Awenius M, et al. Radial multi‐echo bSSFP and IDEAL chemical shift separation in k‐space for high‐speed 3D hyperpolarized 13 C metabolic MRI. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30614