Journal article in Magnetic Resonance in Medicine, 2024. Written by Qingfei Luo and 3 co-authors. Institution: Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA. Major MEDLINE topics: Imaging, Three-Dimensional, Magnetic Resonance Imaging, Brain, Algorithms. 46 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIBIB NIH HHS, NCRR NIH HHS, NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To develop and demonstrate a fast 3D fMRI acquisition technique with high spatial resolution over a reduced FOV, named k‐t 3D reduced FOV imaging (3D‐rFOVI).

Methods

Based on 3D gradient‐echo EPI, k‐t 3D‐rFOVI used a 2D RF pulse to reduce the FOV in the in‐plane phase‐encoding direction, boosting spatial resolution without increasing echo train length. For image acceleration, full sampling was applied in the central k ‐space region along the through‐slab direction ( k z ) for all time frames, while randomized undersampling was used in outer k z regions at different time frames. Images were acquired at 3T and reconstructed using a method based on partial separability. fMRI detection sensitivity of k‐t 3D‐rFOVI was quantitively analyzed with simulation data. Human visual fMRI experiments were performed to evaluate k‐t 3D‐rFOVI and compare it with a commercial multiband EPI sequence.

Results

The simulation data showed that k‐t 3D‐rFOVI can detect 100% of fMRI activations with an acceleration factor ( R ) of 2 and ˜80% with R = 6. In the human fMRI data acquired with 1.5‐mm spatial resolution and 800‐ms volume TR (TR vol ), k‐t 3D‐rFOVI with R = 4 detected 46% more activated voxels in the visual cortex than the multiband EPI. Additional fMRI experiments showed that k‐t 3D‐rFOVI can achieve TR vol of 480 ms with R = 6, while reliably detecting visual activation. Conclusions k‐t 3D‐rFOVI can simultaneously achieve a high spatial resolution (1.5‐mm isotropically) and short TR vol (480‐ms) at 3T. It offers a robust acquisition technique for fast fMRI studies over a focused brain volume.

Subjects

MeSH terms (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance ImagingBrainAlgorithmsHumansBrain MappingAdultImage Processing, Computer-AssistedEcho-Planar ImagingComputer SimulationMaleFemale

Author keywords

(k, t)‐space2D RF pulse3D EPIfast fMRIpartial separabilityrandom undersamplingreduced FOV

Authors and institutions

  • Center for Magnetic Resonance Research, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Department of Radiology, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Department of Biomedical Engineering, University of Illinois at Chicago, Chicago, Illinois, USA.
  • Department of Neurosurgery, University of Illinois at Chicago, Chicago, Illinois, USA.

ORCID profiles: Qingfei Luo, Kaibao Sun, Guangyu Dan, Xiaohong Joe Zhou

Funding

  • NIBIB NIH HHS
  • NCRR NIH HHS
  • NIH HHS
  • National Institutes of Health

Cite

APA

Luo, Q., Sun, K., Dan, G., & Zhou, X. J. (2024). Fast 3D fMRI acquisition with high spatial resolutions over a reduced FOV. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30191

Vancouver

Luo Q, Sun K, Dan G, Zhou XJ. Fast 3D fMRI acquisition with high spatial resolutions over a reduced FOV. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30191

BibTeX
@article{Luo2024,
  author = {Luo, Qingfei and Sun, Kaibao and Dan, Guangyu and Zhou, Xiaohong Joe},
  title = {Fast 3D fMRI acquisition with high spatial resolutions over a reduced FOV},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30191}
}
Start for free →