Accelerated 3D metabolite T 1 mapping of the brain using variable‐flip‐angle SPICE
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30200 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Yibo Zhao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA. Hauptthemen laut MEDLINE: Brain, Phantoms, Imaging, Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIH HHS, NIBIB NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Purpose
To develop a practical method to enable 3D T 1 mapping of brain metabolites. Theory and Methods Due to the high dimensionality of the imaging problem underlying metabolite T 1 mapping, measurement of metabolite T 1 values has been currently limited to a single voxel or slice. This work achieved 3D metabolite T 1 mapping by leveraging a recent ultrafast MRSI technique called SPICE (spectroscopic imaging by exploiting spatiospectral correlation). The Ernst‐angle FID MRSI data acquisition used in SPICE was extended to variable flip angles, with variable‐density sparse sampling for efficient encoding of metabolite T 1 information. In data processing, a novel generalized series model was used to remove water and subcutaneous lipid signals; a low‐rank tensor model with prelearned subspaces was used to reconstruct the variable‐flip‐angle metabolite signals jointly from the noisy data.
Results
The proposed method was evaluated using both phantom and healthy subject data. Phantom experimental results demonstrated that high‐quality 3D metabolite T 1 maps could be obtained and used for correction of T 1 saturation effects. In vivo experimental results showed metabolite T 1 maps with a large spatial coverage of 240 × 240 × 72 mm 3 and good reproducibility coefficients (< 11%) in a 14.5‐min scan. The metabolite T 1 times obtained ranged from 0.99 to 1.44 s in gray matter and from 1.00 to 1.35 s in white matter.
Conclusion
We successfully demonstrated the feasibility of 3D metabolite T 1 mapping within a clinically acceptable scan time. The proposed method may prove useful for both T 1 mapping of brain metabolites and correcting the T 1 ‐weighting effects in quantitative metabolic imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.
- National Center for Supercomputing Applications, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.
- Siemens Medical Solutions USA, Inc., Urbana, Illinois, USA.
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA.
- Department of Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut, USA.
ORCID-Profile: Yibo Zhao, Yudu Li, Rong Guo, Brad Sutton, Chao Ma, Yao Li, Jie Luo
Förderung
- NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Zhao, Y., Li, Y., Guo, R., Jin, W., Sutton, B., Ma, C., El Fakhri, G., Li, Y., Luo, J., & Liang, Z. P. (2024). Accelerated 3D metabolite T 1 mapping of the brain using variable‐flip‐angle SPICE. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30200
Vancouver
Zhao Y, Li Y, Guo R, Jin W, Sutton B, Ma C, et al. Accelerated 3D metabolite T 1 mapping of the brain using variable‐flip‐angle SPICE. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30200
BibTeX
@article{Zhao2024,
author = {Zhao, Yibo and Li, Yudu and Guo, Rong and Jin, Wen and Sutton, Brad and Ma, Chao and El Fakhri, Georges and Li, Yao and Luo, Jie and Liang, Zhi-Pei},
title = {Accelerated 3D metabolite T 1 mapping of the brain using variable‐flip‐angle SPICE},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30200}
}
EUVIMED