Accelerated DESPOT1 with variable parameters for 3D T1 brain mapping
Magnetic Resonance Imaging · 2025
DOI: 10.1016/j.mri.2025.110487 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Ronal Coronado und 6 weiteren Autor:innen. Beteiligte Einrichtung: Núcleo de Investigación en Data Science (NIDS), Facultad de Ingeniería y Negocios, Universidad de Las Américas, Santiago 7500975, Chile; Millennium I…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Imaging, Three-Dimensional, Brain Mapping. Die Arbeit nennt 54 Literaturangaben. Gefördert von: Fondo Nacional de Desarrollo Científico y Tecnológico.
Abstract (Originalsprache)
PURPOSE: Driven equilibrium single pulse observation of T1 (DESPOT1) is a reliable technique for clinical 3D T1 brain mapping. However, its fixed repetition time (TR) and bandwidth (BW) and its linear modeling to estimate T1 conveys to an inefficient imaging protocol. We propose a variable DESPOT1 (vDESPOT1) acquisition and modeling strategy to improve scan efficiency and to accelerate image acquisition. METHODS: vDESPOT1 uses SPGR acquisitions with optimized combinations of TRs, BWs, and FAs, coupled with dictionary-based reconstruction to achieve faster acquisition and more efficient T1 mapping. The proposed vDESPOT1 method was compared to DESPOT1 and inversion recovery spin echo (IR-SE) in phantom and in ten brain healthy subjects. RESULTS: Results demonstrate a reduction in scan time of approximately 40 %, allowing faster 3D brain T1 mapping while maintaining accuracy and T1NR in comparison to conventional DESPOT1. Also, the computational efficiency of a pre-computed dictionary of vDESPOT1 reduces the reconstruction time by ∼50× in comparison linear regression of conventional DESPOT1. Variable BW can enhance scan efficiency without significantly affecting the SNR for T1 when using vDESPOT1. CONCLUSION: These time improvements make vDESPOT1 particularly valuable for dynamic and high-field MRI applications, such as thermal therapy monitoring, pharmacokinetic analysis in DCE-MRI, and imaging in anatomies prone to motion, including the heart, liver, and lungs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Núcleo de Investigación en Data Science (NIDS), Facultad de Ingeniería y Negocios, Universidad de Las Américas, Santiago 7500975, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Biom…
- Imaging, Lawson Research Institute, London, Canada.; Department of Medical Biophysics, Western University, London, Canada.
- Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Institute for Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Biomedical Imaging Center, Ponti…
- Department of Electrical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; School of Biomedical Engineering and Imaging…
- Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Department of Radiology, School of Medicine, Pontificia Universidad Católica de Chile, Santiago, Chile.
- Department of Electrical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Institute for Biological and Medical Enginee…
Förderung
- Fondo Nacional de Desarrollo Científico y Tecnológico
Zitieren
APA
Coronado, R., Varela-Mattatall, G., Sahonero-Alvarez, G., Botnar, R., Besa, C., Irarrazaval, P., & Prieto, C. (2025). Accelerated DESPOT1 with variable parameters for 3D T1 brain mapping. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110487
Vancouver
Coronado R, Varela-Mattatall G, Sahonero-Alvarez G, Botnar R, Besa C, Irarrazaval P, et al. Accelerated DESPOT1 with variable parameters for 3D T1 brain mapping. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110487
BibTeX
@article{Coronado2025,
author = {Coronado, Ronal and Varela-Mattatall, Gabriel and Sahonero-Alvarez, Guillermo and Botnar, René and Besa, Cecilia and Irarrazaval, Pablo and Prieto, Claudia},
title = {Accelerated DESPOT1 with variable parameters for 3D T1 brain mapping},
journal = {Magnetic Resonance Imaging},
year = {2025},
doi = {10.1016/j.mri.2025.110487}
}
EUVIMED