Simultaneous brain and neck time‐of‐flight MRA using spiral multiband with localized quadratic encoding
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.30098 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Xi Peng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Neck, Brain, Signal-To-Noise Ratio. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Royal Philips, Philips.
Abstract (Originalsprache)
Purpose
To develop a method that achieves simultaneous brain and neck time‐of‐flight (ToF) magnetic resonance angiography (MRA) within feasible scan timeframes.
Methods
Localized quadratic (LQ) encoding is efficient for both signal‐to‐noise ratio (SNR) and in‐flow enhancement. We proposed a spiral multiband LQ method to enable simultaneous intracranial and carotid ToF‐MRA within a single scan. To address the venous signal contamination that becomes a challenge with multiband (MB) ToF, tilt‐optimized non‐saturated excitation (TONE) and partial‐Fourier slice selection (PFSS) were further introduced in the LQ framework to mitigate the venous signal and improve artery contrast. A sequential spiral MB and LQ reconstruction pipeline was employed to obtain the brain‐and‐neck image volumes.
Results
The proposed MB method was able to achieve simultaneous brain and neck ToF‐MRA within a 2:50‐min scan. The complementarily boosted SNR‐efficiency by MB and LQ acquisitions allows for the increased spatial coverage without increase in scan time or noticeable compromise in SNR. The incorporation of both TONE and PFSS effectively alleviated the venous contamination with improved small vessel sensitivity. Selection of scan parameters such as the LQ factor and flip angle reflected the trade‐off among SNR, blood contrast, and venous suppression.
Conclusions
A novel MB spiral LQ approach was proposed to enable fast intracranial and carotid ToF‐MRA with minimized venous corruption. The method has shown promise in MRA applications where large spatial coverage is necessary.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
- Department of Radiology, University of Iowa, Iowa City, Iowa, USA.
- Royal Philips, Rochester, Minnesota, USA.
- Department of Radiology, University of Wisconsin, Madison, Wisconsin, USA.
ORCID-Profile: Xi Peng, Dinghui Wang, Daniel Borup, Guruprasad Krishnamoorthy, James G Pipe
Förderung
- Royal Philips
- Philips
Zitieren
APA
Peng, X., Wang, D., Borup, D., Krishnamoorthy, G., & Pipe, J. G. (2024). Simultaneous brain and neck time‐of‐flight MRA using spiral multiband with localized quadratic encoding. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30098
Vancouver
Peng X, Wang D, Borup D, Krishnamoorthy G, Pipe JG. Simultaneous brain and neck time‐of‐flight MRA using spiral multiband with localized quadratic encoding. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30098
BibTeX
@article{Peng2024,
author = {Peng, Xi and Wang, Dinghui and Borup, Daniel and Krishnamoorthy, Guruprasad and Pipe, James G},
title = {Simultaneous brain and neck time‐of‐flight MRA using spiral multiband with localized quadratic encoding},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.30098}
}
EUVIMED