EUVIMEDEUVIMED entdecken
Crossref

Enhanced Blood Suppression in Magnetic Resonance Vessel Wall Imaging Using Toggled DANTE ( tDANTE )

Xiancong Liu iD, Bijia Zhong, Ne Yang, Zhongsen Li iD, Wushi Shao, Haoding Meng, Jing Zou, Aihua Liu, Rui Li

Magnetic Resonance in Medicine · 2027-01 · 97 (1) · 213-224

DOI: 10.1002/mrm.70597 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 21.09.2026. Verfasst von Xiancong Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Image Processing, Computer-Assisted, Intracranial Aneurysm, Magnetic Resonance Imaging. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Beijing Natural Science Fundation project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a method capable of effectively suppressing blood flow signals in arbitrary directions, thereby improving the black‐blood contrast in head‐neck vessel wall imaging (VWI).

Methods

The polarities of gradients in the conventional delay alternating with nutation for tailored excitation (DANTE) module were toggled at each TR, forming three linearly independent black‐blood gradient vectors with a cycle of three TRs, and this proposed technique was named tDANTE. The proposed sequence was applied for head‐neck VWI in healthy volunteers and patients with aneurysms. The imaging performance was comparatively analyzed among the proposed tDANTE‐prepared VWI sequence, standalone VWI sequence and conventional DANTE‐prepared VWI sequence.

Results

In volunteer imaging, the tDANTE sequence achieved further attenuation of blood flow signals, with an overall vessel wall‐to‐lumen contrast‐to‐noise ratio (CNR) of 24.11 ± 9.20. Compared with the standalone VWI sequence and conventional DANTE‐prepared VWI sequence, the CNR increased by 7.3% and 5.9% respectively ( p < 0.001). More prominent black‐blood improvement was observed in tortuous intracranial vessels, compared with straight extracranial vessels. Aneurysm imaging demonstrated that tDANTE significantly reduced luminal signal intensity without causing additional attenuation of aneurysm wall signals. The aneurysm wall CNR increased by 15.9% and 6.3% relative to the two control sequences, enabling clear delineation of aneurysm wall boundaries.

Conclusion

The tDANTE method achieves superior blood suppression performance in head‐neck VWI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyImage Processing, Computer-AssistedIntracranial AneurysmMagnetic Resonance ImagingHumansMaleAdultFemaleAlgorithmsHeadImage EnhancementSignal-To-Noise RatioNeck

Stichwörter der Autor:innen

DANTEaneurysmblack bloodblood suppressionturbo spin echovessel wall imaging

Autor:innen und Institutionen

  • Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University, Beijing, China.
  • Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, Beijing, China.
  • Shanghai United Imaging Healthcare Co. Ltd., Shanghai, China.

ORCID-Profile: Xiancong Liu, Zhongsen Li

Förderung

  • Beijing Natural Science Fundation project

Zitieren

APA

Liu, X., Zhong, B., Yang, N., Li, Z., Shao, W., Meng, H., Zou, J., Liu, A., & Li, R. (2027). Enhanced Blood Suppression in Magnetic Resonance Vessel Wall Imaging Using Toggled DANTE ( tDANTE ). Magnetic Resonance in Medicine, 97(1), 213-224. https://doi.org/10.1002/mrm.70597

Vancouver

Liu X, Zhong B, Yang N, Li Z, Shao W, Meng H, et al. Enhanced Blood Suppression in Magnetic Resonance Vessel Wall Imaging Using Toggled DANTE ( tDANTE ). Magnetic Resonance in Medicine. 2027;97(1):213-224. doi:10.1002/mrm.70597

BibTeX
@article{Liu2027,
  author = {Liu, Xiancong and Zhong, Bijia and Yang, Ne and Li, Zhongsen and Shao, Wushi and Meng, Haoding and Zou, Jing and Liu, Aihua and Li, Rui},
  title = {Enhanced Blood Suppression in Magnetic Resonance Vessel Wall Imaging Using Toggled DANTE ( tDANTE )},
  journal = {Magnetic Resonance in Medicine},
  year = {2027},
  volume = {97},
  number = {1},
  pages = {213--224},
  doi = {10.1002/mrm.70597}
}
Kostenlos starten →