EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling

Hongwei Li iD, Yang Ji iD, He Wang, Zhensen Chen, Tiansheng Qian, Yujun Liao, Jian Wang, Joseph G Woods iD, Yuriko Suzuki iD, Thomas W Okell iD

Magnetic Resonance in Medicine · 2025

DOI: 10.1002/mrm.30542 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Hongwei Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Science and Technology for Brain-inspired Intelligence, Fudan University, Shanghai, People's Republic of China. Hauptthemen laut MEDLINE: Circle of Willis, Moyamoya Disease, Magnetic Resonance Angiography, Image Processing, Computer-Assisted. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Oxford Biomedical Research Centre, Wellcome Trust, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To improve the robustness of noninvasive vessel‐selective perfusion imaging and angiography using vessel‐encoded arterial spin labeling (VEASL) when applied to complex vascular geometries, such as above the circle of Willis (CoW) in the brain.

Methods

Our proposed improved optimized encoding scheme (IOES) better accounts for vascular geometry and the VEASL encoding process, leading to more SNR‐efficient encodings than previous approaches. Pseudo‐continuous arterial spin labeling (PCASL) parameters were optimized for a thinner labeling region, allowing tortuous vessels to be more accurately treated as single points within the labeling plane. Our optimized approach was compared to the original OES method above the CoW in healthy volunteers, with preliminary application in two Moyamoya patients.

Results

In simulation, the IOES improved SNR efficiency by approximately 10% and used longer wavelength encodings that are less sensitive to subject motion. The effective labeling thickness was reduced using optimized PCASL parameters, which maintained high labeling efficiency. In healthy volunteers, these improvements allowed for the separation of at least nine arteries and their downstream tissues, with more accurate vessel decoding and closer alignment between the measured VEASL signal modulation and the encoding design. Vascular territories consistent with angiography were found in the Moyamoya patients.

Conclusions

Combining IOES with optimized PCASL parameters, the vessel‐decoding efficacy in a region with complex vascular geometry above the CoW was improved. The automated encoding design process and scan times under 6 min make it feasible to observe flow patterns above the CoW in clinical settings, particularly for studies of collateral circulation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Circle of WillisMoyamoya DiseaseMagnetic Resonance AngiographyImage Processing, Computer-AssistedHumansSpin LabelsAdultMaleAlgorithmsFemaleBrainSignal-To-Noise RatioHealthy VolunteersComputer SimulationCerebrovascular Circulation

Stichwörter der Autor:innen

SNR efficiencyencoding schemevascular territoryvessel‐encoded arterial spin labeling (VEASL)vessel‐selective

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Institute of Science and Technology for Brain-inspired Intelligence, Fudan University, Shanghai, People's Republic of China.
  • Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK.
  • Department of Electronic Engineering and Information Science, School of Information Science and Technology, University of Science and Technology of China, Hefei, People's Republic of China.
  • MOE Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence, Fudan University, Shanghai, People's Republic of China.
  • Department of Neurosurgery, Fudan University Huashan Hospital, Shanghai, People's Republic of China.
  • Clinical Medical Center of Neurosurgery, Shanghai Key Laboratory of Brain Function and Restoration and Neural Regeneration, Shanghai, People's Republic of China.

ORCID-Profile: Hongwei Li, Yang Ji, Joseph G Woods, Yuriko Suzuki, Thomas W Okell

Förderung

  • NIHR Oxford Biomedical Research Centre
  • Wellcome Trust
  • National Natural Science Foundation of China
  • Natural Science Foundation of Shanghai Municipality
  • Royal Society
  • National Key Research and Development Program of China

Zitieren

APA

Li, H., Ji, Y., Wang, H., Chen, Z., Qian, T., Liao, Y., Wang, J., Woods, J. G., Suzuki, Y., & Okell, T. W. (2025). Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30542

Vancouver

Li H, Ji Y, Wang H, Chen Z, Qian T, Liao Y, et al. Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30542

BibTeX
@article{Li2025,
  author = {Li, Hongwei and Ji, Yang and Wang, He and Chen, Zhensen and Qian, Tiansheng and Liao, Yujun and Wang, Jian and Woods, Joseph G and Suzuki, Yuriko and Okell, Thomas W},
  title = {Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling},
  journal = {Magnetic Resonance in Medicine},
  year = {2025},
  doi = {10.1002/mrm.30542}
}
Kostenlos starten →