Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 25.03.2024. Verfasst von Andreia S Gaspar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Sistemas e Robótica-Lisboa and Departamento de Bioengenharia, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal. Hauptthemen laut MEDLINE: Phantoms, Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Fundação para a Ciência e a Tecnologia, 'la Caixa' Foundation, Programa Operacional Regional de Lisboa.
Abstract (Originalsprache)
Purpose
To develop an open‐source prototype of myocardial T1 mapping (Open‐MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open‐MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter‐scanner and cross‐vendor reproducibility studies.
Methods
Open‐MOLLI is an inversion‐recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open‐MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open‐MOLLI and MOLLI were repeated in the same session (test–retest).
Results
Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1 vial3 = 1027 ms): T1 MOLLI = 1011 ± 24 ms versus T1 Open‐MOLLI = 1009 ± 20 ms. In vivo T1 estimates were similar between Open‐MOLLI and MOLLI (T1 MOLLI = 1004 ± 33 ms vs. T1 Open‐MOLLI = 998 ± 52 ms), with a mean difference of −17 ms ( p = 0.20), despite noisier Open‐MOLLI weighted images and maps. Repeatability measures were slightly higher for Open‐MOLLI (RC MOLLI = 3.0% vs. RC Open‐MOLLI = 4.4%).
Conclusion
The open‐source sequence Open‐MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open‐MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Instituto de Sistemas e Robótica-Lisboa and Departamento de Bioengenharia, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal.
- Hospital da Luz Learning Health, Luz Saúde, Lisboa, Portugal.
- Serviço de Cardiologia, Hospital de Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisboa, Portugal.
- Unidade de Imagiologia Cardíaca Avançada, Hospital da Luz, Lisboa, Portugal.
ORCID-Profile: Andreia S Gaspar, Nuno A Silva, António M Ferreira, Rita G Nunes
Förderung
- Fundação para a Ciência e a Tecnologia
- 'la Caixa' Foundation
- Programa Operacional Regional de Lisboa
- Caixa Foundation
Zitieren
APA
Gaspar, A. S., Silva, N. A., Ferreira, A. M., & Nunes, R. G. (2024). Repeatability of Open‐MOLLI : An open‐source inversion recovery myocardial T1 mapping sequence for fast prototyping. Magnetic Resonance in Medicine, 92(2), 741-750. https://doi.org/10.1002/mrm.30080
Vancouver
Gaspar AS, Silva NA, Ferreira AM, Nunes RG. Repeatability of Open‐MOLLI : An open‐source inversion recovery myocardial T1 mapping sequence for fast prototyping. Magnetic Resonance in Medicine. 2024;92(2):741-750. doi:10.1002/mrm.30080
BibTeX
@article{Gaspar2024,
author = {Gaspar, Andreia S and Silva, Nuno A and Ferreira, António M and Nunes, Rita G},
title = {Repeatability of Open‐MOLLI : An open‐source inversion recovery myocardial T1 mapping sequence for fast prototyping},
journal = {Magnetic Resonance in Medicine},
year = {2024},
volume = {92},
number = {2},
pages = {741--750},
doi = {10.1002/mrm.30080}
}
EUVIMED