EUVIMEDEUVIMED entdecken
Crossref

MyoFold : Joint myocardial tissue composition and wall motion quantification via a highly folded sequence

Rui Guo iD, Yingwei Fan, Bowei Liu, Xiaofeng Qian, Jiahuan Dai iD, Dongyue Si iD, Yuanyuan Wang, Ancong Wang, Guozhao Dong, Yongsheng Jin, Jingjing Xiao, Haiyan Ding und 1 weitere

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Rui Guo und 12 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Technology, Beijing Institute of Technology, Beijing, China. Hauptthemen laut MEDLINE: Heart, Magnetic Resonance Imaging, Cine, Phantoms, Imaging. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China for Young Scholars, Beijing Institute of Technology Research Fund Program for Young Scholars, Beijing Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to develop and evaluate a novel cardiovascular MR sequence, MyoFold, designed for the simultaneous quantifications of myocardial tissue composition and wall motion.

Methods

MyoFold is designed as a 2D single breathing‐holding sequence, integrating joint T 1 /T 2 mapping and cine imaging. The sequence uses a 2‐fold accelerated balanced SSFP (bSSFP) for data readout and incorporates electrocardiogram synchronization to align with the cardiac cycle. MyoFold initially acquires six single‐shot inversion‐recovery images, completed during the diastole of six successive heartbeats. T 2 preparation (T 2 ‐prep) is applied to introduce T 2 weightings for the last three images. Subsequently, over the following six heartbeats, segmented bSSFP is performed for the movie of the entire cardiac cycle, synchronized with an electrocardiogram. A neural network trained using numerical simulations of MyoFold is used for T 1 and T 2 calculations. MyoFold was validated through phantom and in vivo experiments, with comparisons made against MOLLI, SASHA, T 2 ‐prep bSSFP, and the conventional cine.

Results

In phantom studies, MyoFold exhibited a 10% overestimation in T 1 measurements, whereas T 2 measurements demonstrated high accuracy. In vivo experiments revealed that MyoFold T 1 had comparable accuracy to SASHA and precision similar to MOLLI. MyoFold demonstrated good agreement with T 2 ‐prep bSSFP in myocardial T 2 measurements. No significant differences were observed in the quantification of left‐ventricle wall thickness and function between MyoFold and the conventional cine.

Conclusion

MyoFold presents as a rapid, simple, and multitasking approach for quantitative cardiovascular MR examinations, offering simultaneous assessment of tissue composition and wall motion. The sequence's multitasking capabilities make it a promising tool for comprehensive cardiac evaluations in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HeartMagnetic Resonance Imaging, CinePhantoms, ImagingAdultFemaleHumansMaleAlgorithmsElectrocardiographyImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedMyocardiumReproducibility of Results

Stichwörter der Autor:innen

breath‐holdingcinemultitaskingmyocardial T1 and T2 mapping

Autor:innen und Institutionen

  • School of Medical Technology, Beijing Institute of Technology, Beijing, China.
  • Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
  • School of Optics and Photonics, Beijing Institute of Technology, Beijing, China.
  • Department of Infectious Diseases, The Affiliated Hospital of Yan'an University, Shaanxi, China.
  • Bio-Med Informatics Research Center and Clinical Research Center, Xinqiao Hospital, Army Medical University, Chongqing, China.

ORCID-Profile: Rui Guo, Jiahuan Dai, Dongyue Si

Förderung

  • National Natural Science Foundation of China for Young Scholars
  • Beijing Institute of Technology Research Fund Program for Young Scholars
  • Beijing Natural Science Foundation
  • National Natural Science Foundation of China
  • Beijing Institute of Technology

Zitieren

APA

Guo, R., Fan, Y., Liu, B., Qian, X., Dai, J., Si, D., Wang, Y., Wang, A., Dong, G., Jin, Y., Xiao, J., Ding, H., & Tang, X. (2024). MyoFold : Joint myocardial tissue composition and wall motion quantification via a highly folded sequence. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30124

Vancouver

Guo R, Fan Y, Liu B, Qian X, Dai J, Si D, et al. MyoFold : Joint myocardial tissue composition and wall motion quantification via a highly folded sequence. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30124

BibTeX
@article{Guo2024,
  author = {Guo, Rui and Fan, Yingwei and Liu, Bowei and Qian, Xiaofeng and Dai, Jiahuan and Si, Dongyue and Wang, Yuanyuan and Wang, Ancong and Dong, Guozhao and Jin, Yongsheng and Xiao, Jingjing and Ding, Haiyan and Tang, Xiaoying},
  title = {MyoFold : Joint myocardial tissue composition and wall motion quantification via a highly folded sequence},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30124}
}
Kostenlos starten →