Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2023. Verfasst von Saikat Sengupta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Algorithms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NINDS NIH HHS, NIMH NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To achieve high‐resolution multishot echo‐planar imaging (EPI) for functional MRI (fMRI) with reduced sensitivity to in‐plane motion and between‐shot phase variations.

Methods

Two‐dimensional radiofrequency pulses were incorporated in a multishot EPI sequence at 7T which selectively excited a set of in‐plane bands (shutters) in the phase encoding direction, which moved between shots to cover the entire slice. A phase‐ and motion‐corrected reconstruction was implemented for the acquisition. Brain imaging experiments were performed with instructed motion to evaluate image quality for conventional multishot and shuttered EPI. Temporal stability was assessed in three subjects by quantifying temporal SNR (tSNR) and artifact levels, and fMRI activation experiments using visual stimulation were performed to assess the strength and distribution of activation, using both conventional multishot and shuttered EPI.

Results

In the instructed motion experiment, ghosting was lower in shuttered EPI images without or with corrections and image quality metrics were improved with motion correction. tSNR was improved by phase correction in both conventional multishot and shuttered EPI and the acquisitions had similar tSNR without and with phase correction. However, while phase correction was necessary to maximize tSNR in conventional multishot EPI, it also increased intermittent ghosting, but did not increase intermittent ghosting in shuttered EPI. Phase correction increased activation strength in both conventional multishot and shuttered EPI, but caused increased spurious activation outside the brain and in frontal brain regions in conventional multishot EPI.

Conclusion

Shuttered EPI supports multishot segmented EPI acquisitions with lower sensitivity to artifacts from motion for high‐resolution fMRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingAlgorithmsHumansMagnetic Resonance ImagingBrainMotionArtifactsImage Processing, Computer-Assisted

Stichwörter der Autor:innen

2D RFBOLDGRAPPARF pulse designfMRIhigh spatial resolutionimage reconstructionmultishot EPIsegmented EPIultrahigh field

Autor:innen und Institutionen

  • Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee, USA.
  • Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Physics, Carleton University, Ottawa, Ontario, Canada.
  • University of Ottawa Institute of Mental Health Research, Ottawa, Ontario, Canada.
  • Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.
  • Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA.

ORCID-Profile: Saikat Sengupta, Avery Berman, William A Grissom

Förderung

  • NIBIB NIH HHS
  • NINDS NIH HHS
  • NIMH NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Sengupta, S., Berman, A., Polimeni, J. R., Setsompop, K., & Grissom, W. A. (2023). High‐resolution motion‐ and phase‐corrected functional MRI at 7 T using shuttered multishot echo‐planar imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29608

Vancouver

Sengupta S, Berman A, Polimeni JR, Setsompop K, Grissom WA. High‐resolution motion‐ and phase‐corrected functional MRI at 7 T using shuttered multishot echo‐planar imaging. Magnetic Resonance in Medicine. 2023. doi:10.1002/mrm.29608

BibTeX
@article{Sengupta2023,
  author = {Sengupta, Saikat and Berman, Avery and Polimeni, Jonathan R and Setsompop, Kawin and Grissom, William A},
  title = {High‐resolution motion‐ and phase‐corrected functional MRI at 7 T using shuttered multishot echo‐planar imaging},
  journal = {Magnetic Resonance in Medicine},
  year = {2023},
  doi = {10.1002/mrm.29608}
}
Kostenlos starten →