EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Motion compensated structured low‐rank reconstruction for 3D multi‐shot EPI

Xi Chen iD, Wenchuan Wu, Mark Chiew iD

Magnetic Resonance in Medicine · 2024-06 · 91 (6) · 2443-2458

DOI: 10.1002/mrm.30019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 15.02.2024. Verfasst von Xi Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Brain, Algorithms. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Royal Academy of Engineering, Canada Research Chairs.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The 3D multi‐shot EPI imaging offers several benefits including higher SNR and high isotropic resolution compared to 2D single shot EPI. However, it suffers from shot‐to‐shot inconsistencies arising from physiologically induced phase variations and bulk motion. This work proposed a motion compensated structured low‐rank (mcSLR) reconstruction method to address both issues for 3D multi‐shot EPI.

Methods

Structured low‐rank reconstruction has been successfully used in previous work to deal with inter‐shot phase variations for 3D multi‐shot EPI imaging. It circumvents the estimation of phase variations by reconstructing an individual image for each phase state which are then sum‐of‐squares combined, exploiting their linear interdependency encoded in structured low‐rank constraints. However, structured low‐rank constraints become less effective in the presence of inter‐shot motion, which corrupts image magnitude consistency and invalidates the linear relationship between shots. Thus, this work jointly models inter‐shot phase variations and motion corruptions by incorporating rigid motion compensation for structured low‐rank reconstruction, where motion estimates are obtained in a fully data‐driven way without relying on external hardware or imaging navigators.

Results

Simulation and in vivo experiments at 7T have demonstrated that the mcSLR method can effectively reduce image artifacts and improve the robustness of 3D multi‐shot EPI, outperforming existing methods which only address inter‐shot phase variations or motion, but not both.

Conclusion

The proposed mcSLR reconstruction compensates for rigid motion, and thus improves the validity of structured low‐rank constraints, resulting in improved robustness of 3D multi‐shot EPI to both inter‐shot motion and phase variations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrainAlgorithmsImaging, Three-DimensionalMotionEcho-Planar ImagingImage Processing, Computer-AssistedArtifactsDiffusion Magnetic Resonance Imaging

Stichwörter der Autor:innen

3D multi‐shot EPImotion compensationphase variationsstructured low‐rank

Autor:innen und Institutionen

  • Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California, USA.
  • Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, Oxfordshire, UK.
  • Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada.
  • Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.

ORCID-Profile: Xi Chen, Mark Chiew

Förderung

  • Wellcome Trust
  • Royal Academy of Engineering
  • Canada Research Chairs

Zitieren

APA

Chen, X., Wu, W., & Chiew, M. (2024). Motion compensated structured low‐rank reconstruction for 3D multi‐shot EPI. Magnetic Resonance in Medicine, 91(6), 2443-2458. https://doi.org/10.1002/mrm.30019

Vancouver

Chen X, Wu W, Chiew M. Motion compensated structured low‐rank reconstruction for 3D multi‐shot EPI. Magnetic Resonance in Medicine. 2024;91(6):2443-2458. doi:10.1002/mrm.30019

BibTeX
@article{Chen2024,
  author = {Chen, Xi and Wu, Wenchuan and Chiew, Mark},
  title = {Motion compensated structured low‐rank reconstruction for 3D multi‐shot EPI},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  volume = {91},
  number = {6},
  pages = {2443--2458},
  doi = {10.1002/mrm.30019}
}
Kostenlos starten →