Moiré fringes of photon counting grating interferometer with single‐focal‐spot and flat‐panel X‐ray sources
Medical Physics · 2026-08 · 53 (8)
DOI: 10.1002/mp.70594 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, online erschienen am 21.07.2026. Verfasst von Wangjiang Wu und 12 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Southern Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Photons, Interferometry. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Opening Fund of the State Key Laboratory of Optoelectronic Materials and Technologies in Sun Yat-sen University.
Abstract (Originalsprache)
Background
The cold‐cathode flat‐panel X‐ray sources (FPXS) achieve planar integration of X‐ray point sources, which have the potential advantages of cathode addressability and anode patterning tailored to predefined imaging tasks. However, the potential benefits of the FPXS‐based grating interferometer (GI) with photon‐counting detectors (PCD) remain to be determined.
Purpose
In this work, we aim to study if the moiré fringes of the FPXS‐based photon‐counting GI (PCGI) can be formed by utilizing a benchtop system. Materials and methods To address this issue, a dedicated in‐house X‐ray research platform was first built to investigate the X‐ray characteristics of the FPXS, including the X‐ray spectrum and the projection aliasing behaviors. Subsequently, a benchtop FPXS‐based PCGI system was constructed. Due to the projection aliasing of the FPXS, the conventional micro‐focus and large‐focus X‐ray sources were employed to adjust the geometric configurations and the grating postures of the PCGI. As a novel large area X‐ray emission source, the X‐ray emission area sizes and the X‐ray intensities of the FPXS were tuned to investigate if the moiré fringes could be formed under different scenarios. In addition, the moiré patterns of the micro‐focus and large‐focus X‐ray sources were obtained as a baseline for the corresponding FPXS PCGI system.
Results
The current of the FPXS utilized in the study can reach several hundred A at about 40 kV. Moreover, it cannot be independently controlled, which was voltage‐dependent and declined with respect to the exposure time. The projection of the FPXS became less blurred as the X‐ray emission area decreased; however, the number of emitted X‐ray photons was proportionally reduced. The moiré fringes with the single‐focal spot X‐ray sources were reported under different scenarios, such as low X‐ray photon flux, w/wo G0, different energy bins, and different postures of the source. As for the FPXS, however, the moiré fringes were not formulated under different X‐ray emission area sizes and shapes due to the factors, such as projection aliasing, low power, and the system instability.
Conclusions
The unique characteristics of the FPXS were its large‐area X‐ray emission with spatial addressability. While the projection aliasing of FPXS can be largely reduced with small X‐ray emission area size, the X‐ray intensities were also significantly compromised and, thus, prevented formulation of the moiré fringes. In future, the moiré fringes of the FPXS‐based PCGI system with large area X‐ray emission require to be further investigated, such as proposing novel algorithms to obtain the moiré patterns by deblurring the aliased projections.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China.
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-sen University, Guangzho…
- Department of Emergency, The Affiliated TCM Hospital of Guangzhou Medical University, Guangzhou, China.
- Department of Radiation Oncology, Nanfang Hospital, Southern Medical University, Guangzhou, China.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Opening Fund of the State Key Laboratory of Optoelectronic Materials and Technologies in Sun Yat-sen University
Zitieren
APA
Wu, W., Pan, Z., Chen, Y., Wang, Y., Kang, S., Zou, T., Shao, G., Chen, Y., Chen, J., Ma, J., Zhou, L., Xu, Y., & Duan, X. (2026). Moiré fringes of photon counting grating interferometer with single‐focal‐spot and flat‐panel X‐ray sources. Medical Physics, 53(8). https://doi.org/10.1002/mp.70594
Vancouver
Wu W, Pan Z, Chen Y, Wang Y, Kang S, Zou T, et al. Moiré fringes of photon counting grating interferometer with single‐focal‐spot and flat‐panel X‐ray sources. Medical Physics. 2026;53(8). doi:10.1002/mp.70594
BibTeX
@article{Wu2026,
author = {Wu, Wangjiang and Pan, Zengxiang and Chen, Yilin and Wang, Yihang and Kang, Song and Zou, Tian and Shao, Guocong and Chen, Ying and Chen, Jun and Ma, Jianhui and Zhou, Linghong and Xu, Yuan and Duan, Xiaoman},
title = {Moiré fringes of photon counting grating interferometer with single‐focal‐spot and flat‐panel X‐ray sources},
journal = {Medical Physics},
year = {2026},
volume = {53},
number = {8},
doi = {10.1002/mp.70594}
}
EUVIMED