Microfluidic-Integrated, Ring-Resonator-Assisted Mach–Zehnder Interferometer (μFRA-MZI) as a Label-Free Nanophotonic Sensor
Biosensors · 2025
DOI: 10.3390/bios15110741 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Yunju Chang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, University of California, Davis, CA 95616, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Interferometry, Microfluidics. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gordon and Betty Moore Foundation.
Abstract (Originalsprache)
The ring-assisted Mach–Zehnder interferometer (RA-MZI) has high sensitivity and fast optical response time, and it has been used as a label-free nanophotonic biosensor. Most RA-MZI-based biosensors, however, require chemical modification of the ring surface to immobilize biomolecules that can interact with target molecules for sensing. Here, we report a novel microfluidic-integrated RA-MZI (μFRA-MZI) where a microfluidic channel was fabricated right above the photonic ring resonator. μFRA-MZI allows for direct sample delivery to the RA-MZI without chemical modification of the ring surface and measures shifts in the resonance wavelength induced by the presence of target molecules, enabling label-free detection. In order to optimize the sensitivity of μFRA-MZI, seven devices were fabricated with varied design parameters, including the gap distance between the ring and the bus waveguide (Gring), the length of the multi-mode interferometer (LMMI), and the length of the directional coupler (LDC). Photonic characterization showed that the device with Gring = 1.2 μm, LMMI = 15.5 μm, and LDC = 13.5 μm exhibited the highest extinction ratio (ER) compared to the other six devices, consistent with the simulation-optimized design. Testing with NaCl solutions of varying concentrations yielded a bulk sensitivity of 11.48 nm/refractive index unit (RIU) and an ER of 0.41. With the potential to further improve the device’s sensitivity and the ability to detect samples directly in flow without chemical modifications of the ring resonator, μFRA-MZI will provide a robust and effective approach for label-free biosensing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemical Engineering, University of California, Davis, CA 95616, USA.
- Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA.
ORCID-Profile: Zihao Wang, Jiandi Wan
Förderung
- Gordon and Betty Moore Foundation
Zitieren
APA
Chang, Y., Seutter, E. G., Wang, Z., & Wan, J. (2025). Microfluidic-Integrated, Ring-Resonator-Assisted Mach–Zehnder Interferometer (μFRA-MZI) as a Label-Free Nanophotonic Sensor. Biosensors. https://doi.org/10.3390/bios15110741
Vancouver
Chang Y, Seutter EG, Wang Z, Wan J. Microfluidic-Integrated, Ring-Resonator-Assisted Mach–Zehnder Interferometer (μFRA-MZI) as a Label-Free Nanophotonic Sensor. Biosensors. 2025. doi:10.3390/bios15110741
BibTeX
@article{Chang2025,
author = {Chang, Yunju and Seutter, Ethan Glenn and Wang, Zihao and Wan, Jiandi},
title = {Microfluidic-Integrated, Ring-Resonator-Assisted Mach–Zehnder Interferometer (μFRA-MZI) as a Label-Free Nanophotonic Sensor},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15110741}
}
EUVIMED