Balanced plasmonic-augmented silicon photonic interferometric sensor for biosensing applications
Optics Express · 2025
DOI: 10.1364/oe.533570 ↗Kurz gefasst
Fachartikel in der Zeitschrift Optics Express, 2025. Verfasst von Mahmoud A Elrabiaay und 9 weiteren Autor:innen. Hauptthemen laut MEDLINE: Interferometry, Biosensing Techniques, Silicon Compounds, Silicon. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme, Agence Nationale de la Recherche, European Regional Development Fund.
Abstract (Originalsprache)
We demonstrate a self-referenced plasmonic augmented photonic Mach-Zehnder interferometer (MZI) for biosensing applications, incorporating a 70 µm long aluminum plasmonic waveguide in both arms of a silicon nitride (Si 3 N 4 ) MZI. Experimental results matched well with numerical simulations, showing extinction ratio (ER) values that exceed 55 dB and bulk sensitivity of 2322 nm/RIU. Wavelength stability measurements revealed 5×10 −3 nm thermal dependance for an ambient temperature fluctuation of 1-degree Celsius which is 50 times better than a conventional hybrid plasmo-photonic asymmetric MZI (aMZI) configuration, highlighting the robustness of the proposed balanced sensor scheme to ambient temperature fluctuations. Moreover, the experimental results show that the proposed sensor has a limit of detection up to 2.6 ×10 −6 RIU. Surface sensitivity of the proposed sensing transducer was evaluated through a C-reactive protein (CRP) surface saturation measurements and found equal to 10.45 nm/RIU for protein binding. Our validated simulation model was then benchmarked against a diverse set of target bio-analytes (proteins, viruses, bacteria, fungi) with surface sensitivity values reaching up to 2306 nm/RIU, indicating the sensor's heterogeneous detection capabilities. The presented self-referencing sensor configuration offers a cost-effective yet scalable and highly sensitive approach for multiplexed on-chip detection of diverse target analytes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Förderung
- Horizon 2020 Framework Programme
- Agence Nationale de la Recherche
- European Regional Development Fund
- Centre National de la Recherche Scientifique
Zitieren
APA
Elrabiaay, M. A., Eleftheriou, C., Tsekenis, G., Bhalerao, O., Suckow, S., Lemme, M., Das, P., Markey, L., Manolis, A., & Tsiokos, D. (2025). Balanced plasmonic-augmented silicon photonic interferometric sensor for biosensing applications. Optics Express. https://doi.org/10.1364/oe.533570
Vancouver
Elrabiaay MA, Eleftheriou C, Tsekenis G, Bhalerao O, Suckow S, Lemme M, et al. Balanced plasmonic-augmented silicon photonic interferometric sensor for biosensing applications. Optics Express. 2025. doi:10.1364/oe.533570
BibTeX
@article{Elrabiaay2025,
author = {Elrabiaay, Mahmoud A and Eleftheriou, Christia and Tsekenis, George and Bhalerao, Omkar and Suckow, Stephan and Lemme, Max and Das, Pratyusha and Markey, Laurent and Manolis, Athanasios and Tsiokos, Dimitris},
title = {Balanced plasmonic-augmented silicon photonic interferometric sensor for biosensing applications},
journal = {Optics Express},
year = {2025},
doi = {10.1364/oe.533570}
}
EUVIMED