EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose

Simona Facchiano, Ramon Ortiz, Remo Cristoforetti, Naoki D-Kondo, Oliver Jäkel, Bruce Faddegon, Niklas Wahl

Medical Physics · 2026-08 · 53 (8)

DOI: 10.1002/mp.70579 ↗

At a glance

Journal article in Medical Physics, published online on 2026-07-21. Written by Simona Facchiano and 6 co-authors. Institution: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany. Major MEDLINE topics: Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Neoplasms. 65 references. The full text is freely available (open access, CC BY 4.0). Funded by: NCI NIH HHS, NIH HHS, Deutsche Forschungsgemeinschaft.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Nanodosimetry relates the cumulative or statistical moments of Ionization Detail (ID) with biological endpoints of relevance to cancer radiotherapy using charged particles. This association suggests to develop an additional physics‐detailed layer of modeling that may complement biological modeling and treatment planning. The recently introduced cluster dose may serve as a purely physical quantity bridging the Ionization Parameter () to the macroscopic treatment planning scale.

Purpose

In this work, we developed a framework to enable flexible and direct cluster dose optimization using a pencil‐beam algorithm, which we validated with condensed history Monte Carlo (MC) simulations.

Methods

Cluster dose combines the contributions to from all particles within a macroscopic volume. Our framework, implemented in the open source planning toolkit matRad, utilizes the particle and energy‐dependent values from an ID database precomputed from MC track strucure (MCTS) simulations. First, we create pencil‐beam (PB) kernels, including fluence spectra, from condensed history MC simulations. For a water box phantom and a representative prostate patient, we create treatment plans optimized on dose and cluster dose coverage and homogeneity for protons, helium and carbon ions. Plans were validated with Geant4/TOPAS MC.

Results

Our framework provided accurate, practical cluster dose calculation and planning. PB algorithms achieve typical accuracy for cluster dose calculation comparable to dose calculation. Recalculation with TOPAS on the box phantom yielded 3D gamma passing rates (GPRs) greater than . For the prostate patient, GPRs exceeded . Both used the criterion with a threshold of of the maximum dose. Using cluster dose optimization, homogeneous cluster dose target coverage was achieved in all plans. A constant cluster dose prescription across all ion species shows the expected decrease in required absorbed dose for heavier ions.

Conclusions

We demonstrate that fast, direct cluster dose calculation and optimization is feasible using MC validated planning with PB algorithms. Cluster dose prescription and optimization results in the expected cluster dose coverage and physical dose levels depending on the respective primary ion.

Subjects

MeSH terms (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy DosageNeoplasmsRadiometryHumansMaleProstatePhantoms, ImagingProtonsHeliumCarbonIons

Author keywords

Monte Carlo simulationcarbon ionscluster doseheliumionization parameternanodosimetrypencil‐beam algorithmplanningprotonsradiotherapy treatment planning

Substances

ProtonsHeliumCarbonIons

Authors and institutions

  • Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
  • National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany.
  • Faculty of Physics and Astronomy, Heidelberg University, Heidelberg, Germany.
  • Department of Radiation Oncology, University of California San Francisco (UCSF), San Francisco, California, USA.
  • Department of Radiation Oncology, Heidelberg Ion Beam Therapy Center (HIT), University Hospital Heidelberg (UKHD), Heidelberg, Germany.

Funding

  • NCI NIH HHS
  • NIH HHS
  • Deutsche Forschungsgemeinschaft
  • National Institutes of Health

Cite

APA

Facchiano, S., Ortiz, R., Cristoforetti, R., D-Kondo, N., Jäkel, O., Faddegon, B., & Wahl, N. (2026). An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose. Medical Physics, 53(8). https://doi.org/10.1002/mp.70579

Vancouver

Facchiano S, Ortiz R, Cristoforetti R, D-Kondo N, Jäkel O, Faddegon B, et al. An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose. Medical Physics. 2026;53(8). doi:10.1002/mp.70579

BibTeX
@article{Facchiano2026,
  author = {Facchiano, Simona and Ortiz, Ramon and Cristoforetti, Remo and D-Kondo, Naoki and Jäkel, Oliver and Faddegon, Bruce and Wahl, Niklas},
  title = {An ion treatment planning framework for inclusion of nanodosimetric ionization detail through cluster dose},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {8},
  doi = {10.1002/mp.70579}
}
Start for free →