Development of an adjustable dynamic phantom for testing deviceless motion correction algorithm in PET

Christian Kühnel, Tabea Nikola Schmidt, Leonie Schreiber, Holger Ginter, Michael Händel, Martin Freesmeyer, Falk Gühne

Medical Physics · 2026-08 · 53 (8)

DOI: 10.1002/mp.70577 ↗

At a glance

Journal article in Medical Physics, published online on 2026-07-21. Written by Christian Kühnel and 6 co-authors. Institution: Clinic for Nuclear Medicine, University Hospital Jena, Jena, Thuringia, Germany. Major MEDLINE topics: Phantoms, Imaging, Algorithms, Image Processing, Computer-Assisted, Positron-Emission Tomography. 26 references. The full text is freely available (open access, CC BY 4.0).

RésuméSubjectsRéférences bibliographiquesCiteRelated studies

Abstract (original language)

Background

Respiratory motion during PET Imaging leads to blurring, volumetric overestimation, and reduced quantitative accuracy. Deviceless motion correction algorithms (MCA) such as OncoFreeze (OF) by Siemens Healthineers (Forchheim, Germany) extract respiratory waveforms from list‐mode data but require validation that cannot be obtained in vivo.

Purpose

To develop and validate an adjustable dynamic phantom with fillable spheres for quantitative assessment of deviceless PET motion correction.

Methods

A microprocessor‐controlled two‐axis phantom was constructed to generate linear craniocaudal (cc), ventrodorsal (vd), and diagonal (diag) motion with amplitudes of 0–40 mm and frequencies of 10–40 min − 1 . Polymethylmethacrylate (PMMA) spheres (4, 1, and 0.25 mL) filled with 1 8 F‐fluorodeoxyglucose (FDG) were placed in a water‐filled PMMA tank and imaged on a Biograph Vision 600 PET/CT (Siemens Healthineers AG, Forchheim, Germany). For each sphere and direction, 2‐min PET scans were acquired with and without MCA, yielding 288 datasets. Volumes, activities, and recovery coefficients (RCs) were extracted using two different isocontours.

Results

Without correction, motion produced substantial overestimation of apparent volume: +15%–55% (4 mL), +81%–166% (1 mL) and +276%–509% (0.25 mL), depending on trajectory and IC 37 . MCA reduced these distortions: For the 1 mL sphere from +87% to −8% (vd) and +166% to +82% (diag). IC 0.1 ‐based activity remained within ≈1%–2% of the nominal value and was minimally affected by MCA, while IC 37 underestimated activity (∼45%) and was direction‐dependently altered by correction. RCs increased with sphere size and were partially improved by MCA but not restored to static levels.

Conclusions

The phantom provides a reproducible ground‐truth framework for evaluating deviceless PET motion correction. MCA reduces motion‐induced blurring and volumetric inflation, though correction remains size‐ and direction‐dependent. The system enables systematic benchmarking and further optimization of motion‐correction algorithms.

Subjects

MeSH terms (MEDLINE)

Phantoms, ImagingAlgorithmsImage Processing, Computer-AssistedPositron-Emission TomographyMovementPolymethyl Methacrylate

Substances

Polymethyl Methacrylate

Authors and institutions

  • Clinic for Nuclear Medicine, University Hospital Jena, Jena, Thuringia, Germany.
  • Central Research Facilities, University Hospital Jena, Jena, Thuringia, Deutschland.

Cite

APA

Kühnel, C., Schmidt, T. N., Schreiber, L., Ginter, H., Händel, M., Freesmeyer, M., & Gühne, F. (2026). Development of an adjustable dynamic phantom for testing deviceless motion correction algorithm in PET. Medical Physics, 53(8). https://doi.org/10.1002/mp.70577

Vancouver

Kühnel C, Schmidt TN, Schreiber L, Ginter H, Händel M, Freesmeyer M, et al. Development of an adjustable dynamic phantom for testing deviceless motion correction algorithm in PET. Medical Physics. 2026;53(8). doi:10.1002/mp.70577

BibTeX
@article{Khnel2026,
  author = {Kühnel, Christian and Schmidt, Tabea Nikola and Schreiber, Leonie and Ginter, Holger and Händel, Michael and Freesmeyer, Martin and Gühne, Falk},
  title = {Development of an adjustable dynamic phantom for testing deviceless motion correction algorithm in PET},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {8},
  doi = {10.1002/mp.70577}
}
Start for free →