EUVIMEDEUVIMED entdecken
Open Access

A synergistic framework for geometric calibration and reconstruction in dual‐arm robotic cone‐beam computed tomography

Zeyu Lai, Shousheng Luo, Xiaohong Fan, Shijie Wang, Xiaoqin Xia, Dexing Kong

Medical Physics · 2026-07 · 53 (7)

DOI: 10.1002/mp.70558 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, online erschienen am 10.07.2026. Verfasst von Zeyu Lai und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematical Sciences, Zhejiang University, Hangzhou, China. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Robotics, Image Processing, Computer-Assisted. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dual‐arm robotic cone‐beam computed tomography (CBCT) systems are susceptible to geometric instability due to their decoupled kinematics, which can limit their practical application.

Purpose

This study aims to develop and evaluate a synergistic framework for improving geometric calibration and reconstruction consistency in flexible dual‐arm robotic CBCT platforms.

Methods

We introduce the Synergistic Calibration and Reconstruction (SyCaR) framework. It uses a two‐stage geometric calibration strategy that combines real‐time external metrology for projection‐wise pose estimation with an optional reference‐free projection‐consistency refinement for residual geometric correction. For reconstruction, we developed a Pose‐Driven Feldkamp‐Davis‐Kress (PD‐FDK) algorithm that operates directly on per‐projection pose data to account for detector misalignments and non‐ideal source‐detector trajectory deviations.

Results

Physical phantom experiments showed that encoder geometry produced severe streaking artifacts and structural inconsistency, whereas motion‐capture geometry restored clearer phantom structures. In the numerical study, PD‐FDK achieved the best PSNR and RMSE among the evaluated analytical methods, improving from 28.99 dB and 0.036 with standard FDK to 32.72 dB and 0.023. Across numerical and physical experiments, PD‐FDK reduced geometry‐related artifacts and showed consistent performance among FDK type methods under the tested conditions.

Conclusions

The proposed SyCaR framework provides a feasible computational approach for mitigating geometric instability in dual‐arm robotic CBCT. The combination of geometric calibration and PD‐FDK reconstruction improved reconstruction consistency and reduced geometry‐related artifacts under the evaluated numerical and physical settings, while retaining the computational efficiency of analytical reconstruction. This work supports the further development of flexible dual‐arm robotic CBCT for biomedical imaging applications, although broader validation with more diverse trajectories, objects, and acquisition conditions remains necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyRoboticsImage Processing, Computer-AssistedCalibrationPhantoms, ImagingAlgorithmsArtifacts

Stichwörter der Autor:innen

cone beam CTgeometric calibrationrobotic CT

Autor:innen und Institutionen

  • School of Mathematical Sciences, Zhejiang University, Hangzhou, China.
  • College of Mathematical Medicine, Zhejiang Normal University, Jinhua, China.

Zitieren

APA

Lai, Z., Luo, S., Fan, X., Wang, S., Xia, X., & Kong, D. (2026). A synergistic framework for geometric calibration and reconstruction in dual‐arm robotic cone‐beam computed tomography. Medical Physics, 53(7). https://doi.org/10.1002/mp.70558

Vancouver

Lai Z, Luo S, Fan X, Wang S, Xia X, Kong D. A synergistic framework for geometric calibration and reconstruction in dual‐arm robotic cone‐beam computed tomography. Medical Physics. 2026;53(7). doi:10.1002/mp.70558

BibTeX
@article{Lai2026,
  author = {Lai, Zeyu and Luo, Shousheng and Fan, Xiaohong and Wang, Shijie and Xia, Xiaoqin and Kong, Dexing},
  title = {A synergistic framework for geometric calibration and reconstruction in dual‐arm robotic cone‐beam computed tomography},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {7},
  doi = {10.1002/mp.70558}
}
Kostenlos starten →