EUVIMEDOdkrijte EUVIMED
Crossref

A novel optical respiratory gating system with a hybrid phase‐amplitude algorithm for spot‐scanning proton therapy

Mikhail A Belikhin, Alexander E Shemyakov, Irina N Zavestovskaya, Alexander A Pryanichnikov

Medical Physics · 2026-07 · 53 (7)

DOI: 10.1002/mp.70544 ↗

At a glance

Journal article in Medical Physics, published online on 2026-06-30. Written by Mikhail A Belikhin and 3 co-authors. Institution: Department of Biomedical Technologies, Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia. Major MEDLINE topics: Proton Therapy, Algorithms, Respiration. 35 references. Funded by: Ministry of Science and Higher Education of the Russian Federation.

PovzetekSubjectsBibliografski podatkiCiteRelated studies

Abstract (original language)

Background

Respiratory motion remains a major challenge in thoracic and abdominal proton treatments, causing interplay effects and dose distortions. In synchrotron‐based systems, conventional gating significantly prolongs beam delivery and overall treatment time, which limits its clinical applicability and patient suitability.

Purpose

The present study was aimed to investigation of the gating system with the novel hybrid phase‐amplitude algorithm specified for synchrotron‐based proton therapy systems with spot‐scanning beam delivery in the phantom test. This system was experimentally evaluated for robustness to target motion irregularities in terms of dose distortion and irradiation time.

Methods

A dynamic phantom simulated the free‐breathing motion using a radiochromic film immersed in water. The film was irradiated in a single fraction with gating for regular and irregular motion patterns. The phase‐amplitude gating algorithm was implemented to provide two‐signal control of the synchrotron for beam injection and extraction. The measured dose distributions were analyzed using gamma index calculation with a 5%/3 mm criterion.

Results

Gating mitigated the interplay effect, resulting in a gamma passing rate (GPR) of 98.5 ± 0.1% (mean ± SD) at regular motion, but the irradiation time was increased from 155 ± 2 s (mean ± SD) to 209 ± 9 s compared to no gating. The GPR fluctuated unsystematically as a function of motion irregularity ( p = 0.111), resulting in a median GPR of 96.0% (range 89.2%‐98.6%), and the irradiation time increased from 209 ± 9 s to 238 ± 8 s compared to regular motion ( p = 0.002). Robustness to random motion irregularities up to 30% resulted in 67% acceptable dose distributions and 14% increase in irradiation time.

Conclusions

The algorithm ensured full synchronization of beam injection and extraction with the respiratory cycle, which allowed a significant reduction in treatment time. The phase‐amplitude gating together with fractionation and rescanning can be potentially effective in the treatment of thoracic and abdominal tumors using synchrotron‐based systems with scanning beams. The introduction of a system‐specific quantitative threshold for patient respiratory irregularity is mandatory for deciding to use gated treatment or not.

Subjects

MeSH terms (MEDLINE)

Proton TherapyAlgorithmsRespirationPhantoms, ImagingHumansMovementSynchrotronsRadiotherapy Dosage

Author keywords

gating deviceinterplay effectintrafractional motionrespiratory irregularityrespiratory‐gated proton therapy

Authors and institutions

  • Department of Biomedical Technologies, Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia.
  • Department of Radiation Oncology, Dmitry Rogachev National Research Center of Pediatric Hematology, Oncology and Immunology, Moscow, Russia.
  • Institute of Biomedical Engineering, Karlsruhe Institute of Technology, Karlsruhe, Germany.

Funding

  • Ministry of Science and Higher Education of the Russian Federation

Cite

APA

Belikhin, M. A., Shemyakov, A. E., Zavestovskaya, I. N., & Pryanichnikov, A. A. (2026). A novel optical respiratory gating system with a hybrid phase‐amplitude algorithm for spot‐scanning proton therapy. Medical Physics, 53(7). https://doi.org/10.1002/mp.70544

Vancouver

Belikhin MA, Shemyakov AE, Zavestovskaya IN, Pryanichnikov AA. A novel optical respiratory gating system with a hybrid phase‐amplitude algorithm for spot‐scanning proton therapy. Medical Physics. 2026;53(7). doi:10.1002/mp.70544

BibTeX
@article{Belikhin2026,
  author = {Belikhin, Mikhail A and Shemyakov, Alexander E and Zavestovskaya, Irina N and Pryanichnikov, Alexander A},
  title = {A novel optical respiratory gating system with a hybrid phase‐amplitude algorithm for spot‐scanning proton therapy},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {7},
  doi = {10.1002/mp.70544}
}
Start for free →