EUVIMEDScopri EUVIMED
Open access · CC BY 4.0

Development of a practical and high‐speed deep learning‐based dose calculation model in boron neutron capture therapy for head and neck cancer

Ryohei Kato iD, Noriyuki Kadoya iD, Takahiro Kato iD, Akihiko Takeuchi iD, Shinya Komori iD, Keiichi Jingu iD, Yoshihiro Takai

Medical Physics · 2026

DOI: 10.1002/mp.70497 ↗

At a glance

Journal article in Medical Physics, 2026. Written by Ryohei Kato and 6 co-authors. Institution: Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, Koriyama, Fukushima, Japan. Major MEDLINE topics: Boron Neutron Capture Therapy, Head and Neck Neoplasms, Radiotherapy Planning, Computer-Assisted, Deep Learning. 39 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

In boron neutron capture therapy (BNCT), Monte Carlo (MC) dose calculations are commonly employed because of the complicated neutron reactions. However, MC dose calculations are generally time‐consuming. Recently, deep learning (DL)‐based dose prediction/calculation has attracted increasing attention; however, the applications of DL models in BNCT are limited and have not been investigated extensively. In addition, there are no practical DL models that can be employed in BNCT clinical practice.

Purpose

We propose a practical DL model for head and neck cancers using a commercial treatment planning system (TPS) for BNCT. To increase the speed of the MC dose calculations, the proposed DL model converts the BNCT dose components calculated by the coarse dose calculation grid size and low statistical uncertainty in the MC calculation into the dose components calculated under the fine setting.

Methods

In this study, we considered 114 head and neck cancer patients who underwent accelerator‐based BNCT at our center. Here, we randomly divided 102 patients for training/validation and 12 patients for testing. The BNCT dose components (i.e., boron, nitrogen, hydrogen, and gamma doses) were calculated for all patients using a commercial TPS for BNCT. We employed the hierarchically dense U‐net and converted the BNCT dose components calculated by the coarse setting (grid size/uncertainty = 5 mm/10%) into doses calculated by the fine setting (2 mm/5%). In addition, a physical density map was added to the DL input to improve the conversion accuracy. Taking the fine dose as the ground truth, we evaluated the γ‐passing rates with various criteria for each dose component of the coarse and DL doses. The calculation time was also measured in the fine, coarse, and DL doses.

Results

In the boron dose, the DL dose exhibited significantly higher γ‐passing rates of ≥ 95% with a criterion of 1%/2 mm (dose difference/distance to agreement) than the coarse dose. In the nitrogen and hydrogen doses, the DL dose also demonstrated high γ‐passing rates of 95.3% and 94.7% with a criterion of 5%/2 mm. The density map was effective for the hydrogen and nitrogen doses. In addition, the average γ‐passing rate with the criterion of 3%/2 mm in the gamma dose achieved 96.2% for the DL dose. The average calculation times for the fine and coarse settings were 984.2 ± 470.2 min and 11.0 ± 2.9 min, respectively, and the average conversion time in the DL model was 0.091 ± 0.020 min.

Conclusions

In this study, the proposed DL model was developed to convert each dose component calculated in the coarse setting to the fine dose to increase the speed of commercial MC dose calculations in BNCT for head and neck cancers. The conversion speed from the coarse dose to the fine dose was considerably rapid, and its performance was highly accurate. The proposed DL model can provide accurate BNCT dose distributions at high speed, thereby contributing to improving the quality of BNCT treatment planning.

Subjects

MeSH terms (MEDLINE)

Boron Neutron Capture TherapyHead and Neck NeoplasmsRadiotherapy Planning, Computer-AssistedDeep LearningRadiation DosageHumansRadiotherapy DosageMonte Carlo MethodTime Factors

Author keywords

boron neutron capture therapydeep learninghead and neckmonte carlotreatment planning

Authors and institutions

  • Department of Radiation Physics and Technology, Southern Tohoku BNCT Research Center, Koriyama, Fukushima, Japan.
  • Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Miyagi, Japan.
  • Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Fukushima, Japan.
  • Department of Radiation Oncology, Southern Tohoku BNCT Research Center, Koriyama, Fukushima, Japan.

ORCID profiles: Ryohei Kato, Noriyuki Kadoya, Takahiro Kato, Akihiko Takeuchi, Shinya Komori, Keiichi Jingu

Cite

APA

Kato, R., Kadoya, N., Kato, T., Takeuchi, A., Komori, S., Jingu, K., & Takai, Y. (2026). Development of a practical and high‐speed deep learning‐based dose calculation model in boron neutron capture therapy for head and neck cancer. Medical Physics. https://doi.org/10.1002/mp.70497

Vancouver

Kato R, Kadoya N, Kato T, Takeuchi A, Komori S, Jingu K, et al. Development of a practical and high‐speed deep learning‐based dose calculation model in boron neutron capture therapy for head and neck cancer. Medical Physics. 2026. doi:10.1002/mp.70497

BibTeX
@article{Kato2026,
  author = {Kato, Ryohei and Kadoya, Noriyuki and Kato, Takahiro and Takeuchi, Akihiko and Komori, Shinya and Jingu, Keiichi and Takai, Yoshihiro},
  title = {Development of a practical and high‐speed deep learning‐based dose calculation model in boron neutron capture therapy for head and neck cancer},
  journal = {Medical Physics},
  year = {2026},
  doi = {10.1002/mp.70497}
}
Start for free →