Proton dose calculation with transformer: Transforming spot map to dose
Medical Physics · 2025
DOI: 10.1002/mp.17794 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Xueyan Tang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Proton Therapy, Radiation Dosage. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben.
Abstract (Originalsprache)
Background
Conventional proton dose calculation methods are either time‐ and resource‐intensive, like Monte Carlo (MC) simulations, or they sacrifice accuracy, as seen with analytical methods. This trade‐off between computational efficiency and accuracy highlights the need for improved dose calculation approaches in clinical settings.
Purpose
This study aims to develop a deep‐learning‐based model that calculates dose‐to‐water ( D W ) and dose‐to‐medium ( D M ) using patient anatomy and proton spot map (PSM), achieving approaching MC‐level accuracy with significantly reduced computation time. Additionally, the study seeks to generalize the model to different treatment sites using transfer learning.
Methods
A SwinUNetr model was developed using 259 four‐field prostate proton stereotactic body radiation therapy (SBRT) plans to calculate patient‐specific D W and D M distributions from CT and projected PSM (PPSM). The PPSM was created by projecting PSM into the CT scans using spot coordinates, stopping power ratio, beam divergence, and water‐equivalent thickness. Fine‐tuning was then performed for the central nervous system (CNS) site using 84 CNS plans. The model's accuracy was evaluated against MC simulation benchmarks using mean absolute error (MAE), gamma analysis (2% local dose difference, 2‐mm distance‐to‐agreement, 10% low dose threshold), and relevant clinical indices on the test dataset.
Results
The trained model achieved a single‐field dose calculation time of 0.07 s on a Nvidia‐A100 GPU, over 100 times faster than MC simulators. For the prostate site, the best‐performing model showed an average MAE of 0.26 ± 0.17 Gy and a gamma index of 92.2% ± 3.1% in dose regions above 10% of the maximum dose for D W calculations, and an MAE of 0.30 ± 0.19 Gy with a gamma index of 89.7% ± 3.9% for D M calculations. After transfer learning for CNS plans, the model achieved an MAE of 0.49 ± 0.24 Gy and a gamma index of 90.1% ± 2.7% for D W computations, and an MAE of 0.47 ± 0.25 Gy with a gamma index of 85.4% ± 7.1% for D M computations.
Conclusions
The SwinUNetr model provides an efficient and accurate method for computing dose distributions in proton therapy. It also opens the possibility of reverse‐engineering PSM from D W , potentially speeding up treatment planning while maintaining accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota, USA.
Zitieren
APA
Tang, X., Tseung, H. W. C., Pepin, M. D., Johnson, J. E., Moseley, D. J., Routman, D. M., & Qian, J. (2025). Proton dose calculation with transformer: Transforming spot map to dose. Medical Physics. https://doi.org/10.1002/mp.17794
Vancouver
Tang X, Tseung HWC, Pepin MD, Johnson JE, Moseley DJ, Routman DM, et al. Proton dose calculation with transformer: Transforming spot map to dose. Medical Physics. 2025. doi:10.1002/mp.17794
BibTeX
@article{Tang2025,
author = {Tang, Xueyan and Tseung, Hok Wan Chan and Pepin, Mark D and Johnson, Jed E and Moseley, Doug J and Routman, David M and Qian, Jing},
title = {Proton dose calculation with transformer: Transforming spot map to dose},
journal = {Medical Physics},
year = {2025},
doi = {10.1002/mp.17794}
}
EUVIMED