EUVIMEDSkopri EUVIMED
Open access · CC BY 4.0

Determining a Gamma Knife's isocenter using a starburst shot

Robert Corns, Kainoa Calistro-Allen, Kaida Yang, Jae Jung, Yanan Cao, Wesley Belcher

Medical Physics · 2026-04 · 53 (4)

DOI: 10.1002/mp.70434 ↗

At a glance

Journal article in Medical Physics, published online on 2026-04-20. Written by Robert Corns and 5 co-authors. Institution: Department of Radiation Oncology, Brody School of Medicine, East Carolina University, Greenville, North Carolina, USA. Major MEDLINE topics: Radiosurgery. 11 references. The full text is freely available (open access, CC BY 4.0). Funded by: East Carolina University.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

The Gamma Knife is an important treatment unit for stereotactic radiosurgery. The isocenter is well understood from the collective behavior of all its 192 Co60 sources but is not known from the behavior of individual sources.

Purpose

To introduce and validate the “starburst shot,” a new quality assurance (QA) technique to better understand the Gamma Knife's isocenter by analyzing the convergence of all individual collimator beam axes.

Methods

We built cylindrical phantoms to acquire panoramic radiographic films for 4‐, 8‐, and 16‐mm collimator sizes. We developed an algorithm to locate the centers of each entrance and corresponding exit exposure on the panoramic film, map their centers back to the cylinder, and connect the centers with a line segment in 3D. These lines represent the collimators’ central axes, and we analyzed the resulting cluster of 192 lines using an optimization algorithm to locate the smallest sphere that simultaneously touches all lines. This sphere's center is an estimate of the isocenter, and the radial distances from the isocenter were scored by the probability of passing within 0.5 mm of the isocenter.

Results

This optimization method provided a robust determination of the isocenter. For the 4‐mm collimators, was 1.00. For the 8‐mm collimators, ranged from 0.81 to 0.93, and for the 16‐mm collimators, it ranged from 0.74 to 0.92. The isocenters determined for the 4‐, 8‐, and 16‐mm collimators were found to be within 0.2 mm of each other. In a double‐exposure experiment, the starburst shot accurately found a 1‐mm shift introduced between exposures.

Conclusions

The starburst shot is a new, effective technique for detailed Gamma Knife isocenter QA, providing a comprehensive analysis of all 192 beams. It successfully verifies the isocenter's position and size with submillimeter accuracy. The starburst shot differs significantly from standard techniques, such as the pinprick tool test, and we propose a tiered system of acceptable values of 0.90 for 4 mm, 0.80 for 8 mm, and 0.70 for 16 mm, as a QA standard for clinical use.

Subjects

MeSH terms (MEDLINE)

RadiosurgeryPhantoms, ImagingAlgorithms

Author keywords

Gamma KnifeSRSisocenterpanoramicquality assurancestarburst shot

Authors and institutions

  • Department of Radiation Oncology, Brody School of Medicine, East Carolina University, Greenville, North Carolina, USA.
  • Department of Radiology, Heersink School of Medicine, University of Alabama at Birmingham, Birmingham, Alabama, USA.
  • Department of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York City, New York, USA.

Funding

  • East Carolina University

Cite

APA

Corns, R., Calistro-Allen, K., Yang, K., Jung, J., Cao, Y., & Belcher, W. (2026). Determining a Gamma Knife's isocenter using a starburst shot. Medical Physics, 53(4). https://doi.org/10.1002/mp.70434

Vancouver

Corns R, Calistro-Allen K, Yang K, Jung J, Cao Y, Belcher W. Determining a Gamma Knife's isocenter using a starburst shot. Medical Physics. 2026;53(4). doi:10.1002/mp.70434

BibTeX
@article{Corns2026,
  author = {Corns, Robert and Calistro-Allen, Kainoa and Yang, Kaida and Jung, Jae and Cao, Yanan and Belcher, Wesley},
  title = {Determining a Gamma Knife's isocenter using a starburst shot},
  journal = {Medical Physics},
  year = {2026},
  volume = {53},
  number = {4},
  doi = {10.1002/mp.70434}
}
Start for free →