A respiratory motion analysis for guiding stereotactic arrhythmia radiotherapy motion management
Medical Physics · 2026
DOI: 10.1002/mp.70323 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Physics, 2026. Verfasst von Yuhao Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, School of Medicine, Duke University, Durham, North Carolina, USA. Hauptthemen laut MEDLINE: Respiration, Radiosurgery, Radiotherapy, Image-Guided, Arrhythmias, Cardiac. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, NHLBI NIH HHS, National Institute of Biomedical Imaging and Bioengineering (NIBIB).
Abstract (Originalsprache)
Background
Stereotactic arrhythmia radiotherapy (STAR) treats ventricular tachycardia (VT) but requires internal target volume (ITV) expansions to compensate for cardiorespiratory motion. Respiratory 4D CTs (r4DCT) are commonly acquired for STAR patients to assess respiratory motion and determine the ITV expansion margin. Current clinical r4DCT imaging methods are limited, and the reconstructed r4DCTs suffer from unmanaged cardiac motion artifacts that affect the quantitative assessment of respiratory motion of the heart and substructures.
Purpose
To develop a novel image‐processing method that accurately quantifies the respiratory motion of the heart and substructures in r4DCTs corrupted by cardiac motion artifacts.
Methods
A groupwise surface‐to‐surface deformable image registration (DIR) algorithm, named gCGF, was developed by combining the Coherent Point Drift (CPD) algorithm with Gaussian Mixture Models (GMM) and a Finite Element Model (FEM). A novel principal component filtering (PCF) mechanism and a spatial smoothing mechanism were developed and incorporated into gCGF to iteratively register heart contours of ten r4DCT phases while removing random cardiac motion from the cyclic respiratory motion. The performance of the groupwise DIR was quantitatively validated using eight digital phantoms with simulated cardiac artifacts. An ablation study was conducted to compare gCGF to another comparable state‐of‐the‐art groupwise DIR method. gCGF was applied to r4DCTs of 20 STAR patients to analyze the respiratory motion of the heart, which was computed for individual respiratory phases, with the average position of registered heart shapes as the reference position.
Results
Validation on digital phantoms showed that gCGF achieved target registration errors (TRE) of 0.63 ± 0.51 mm for the heart surface while successfully achieving phase smoothness and reducing cardiac motion artifacts. TREs of 0.69 to 0.95 mm were achieved for the cardiac substructures. For each STAR patient, the heart contours of ten phases of r4DCT were registered with gCGF. Among all STAR patients, the heart's maximum and mean respiratory motion magnitudes ranged from 3.6 to 7.9 mm and 1.0 to 2.6 mm. The peak‐to‐peak motion range was from 6.2 to 14.7 mm. For VT targets, the max and mean motion magnitude ranges were 3.0 to 6.7 mm and 0.8 to 2.9 mm, respectively. The peak‐to‐peak range was from 4.7 to 11.8 mm. Significant dominance of the first principal component of the motion direction was observed ( p = 0). Respiratory motion was found to be patient‐specific and predominantly in the first principal component direction.
Conclusions
The gCGF surface‐to‐surface deformable registration algorithm was confirmed to be robust to quantify respiratory motion of the heart in the r4DCTs while mitigating cardiac motion artifacts. The gCGF algorithm and the results of this study can be useful to enable personalized motion management for STAR treatments and patient‐specific optimization of the ITV margins.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, School of Medicine, Duke University, Durham, North Carolina, USA.
- Department of Radiation Oncology, School of Medicine, Washington University in Saint Louis, St. Louis, Missouri, USA.
- Department of Radiology, School of Medicine, Washington University in Saint Louis, St. Louis, Missouri, USA.
- Department of Biomedical Engineering, Washington University in Saint Louis, St. Louis, Missouri, USA.
- Department of Cardiology, School of Medicine, Washington University in Saint Louis, St. Louis, Missouri, USA.
Förderung
- NIBIB NIH HHS
- NHLBI NIH HHS
- National Institute of Biomedical Imaging and Bioengineering (NIBIB)
- National Heart, Lung, and Blood Institute (NHLBI)
Zitieren
APA
Wang, Y., Hao, Y., An, H., Gach, H. M., Robinson, C. G., Cuculich, P. S., & Yang, D. (2026). A respiratory motion analysis for guiding stereotactic arrhythmia radiotherapy motion management. Medical Physics. https://doi.org/10.1002/mp.70323
Vancouver
Wang Y, Hao Y, An H, Gach HM, Robinson CG, Cuculich PS, et al. A respiratory motion analysis for guiding stereotactic arrhythmia radiotherapy motion management. Medical Physics. 2026. doi:10.1002/mp.70323
BibTeX
@article{Wang2026,
author = {Wang, Yuhao and Hao, Yao and An, Hongyu and Gach, H Michael and Robinson, Clifford G and Cuculich, Phillip S and Yang, Deshan},
title = {A respiratory motion analysis for guiding stereotactic arrhythmia radiotherapy motion management},
journal = {Medical Physics},
year = {2026},
doi = {10.1002/mp.70323}
}
EUVIMED