Remote sensing of high energy particle current generated by megavoltage x‐rays

Arith Rajapakse, Coral Outwater, Davide Brivio, Erno Sajo, Piotr Zygmanski

Medical Physics · 2025

DOI: 10.1002/mp.17756 ↗

At a glance

Journal article in Medical Physics, 2025. Written by Arith Rajapakse and 4 co-authors. Institution: Department of Radiation Oncology, Dana Farber Cancer Institute and Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA. Major MEDLINE topics: Radiometry. Cited 1 times so far (Crossref); 20 references. The full text is freely available in PubMed Central. Funded by: 2023 Summer Undergraduate Fellowship Program.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

In x‐ray radiography and computed tomography (CT), absorbed dose is deposited in a radiation detector array in the form of charge carriers and collected. While these modalities are the standard for clinical imaging during the radiation therapy process, they require the use of bulk materials and adequate operating voltages. These constraints leave space for an imaging/dosimetry niche favoring low profile, low power, and non‐invasive modalities.

Purpose

The conversion of therapeutic radiation to absorbed dose begins with the generation of high energy electrons. If utilized correctly, the high energy particle currents (HEC) offer a unique prospect for a novel form of imaging and dosimetry. In this paper, we establish the theoretical and experimental framework behind the sensing of HEC by measuring currents in various homogeneous and heterogeneous phantoms and comparing the measured signals to both one‐dimensional particle transport and Monte Carlo (MC) based simulations.

Methods

The experimental setup for HEC sensing consists of pairs of complementary electrodes placed upstream and downstream of the object or phantom in question. When irradiated with 6MV x‐rays, two signals, s 1 , and s 2 , were collected with zero external bias. These signals are coupled to each other due to the distribution of HEC inside the phantom. Both homogeneous (water) and heterogeneous (water and bone) phantoms were irradiated, and the measured signals were reviewed against simulations (MCNP6, CEPXS).

Results

The measured signals s 1 and s 2 (as a function of water equivalent thickness [WET]) for homogeneous phantoms matched the trends established by the corresponding radiation transport simulations; indicating that these signals convey information about the distribution of HEC inside the phantoms. Based on these findings, new signal metrics, α and β , were formalized and used to quantify the scanning of heterogeneous phantoms.

Conclusion

In this work, we demonstrated that information about the internal composition of an object can be obtained through HEC sensing. Specifically, the distribution of HEC inside of an object resulting from x‐ray irradiation was measured using a simple system of planar electrodes and agreed well with radiation transport simulations. HEC sensing has the potential to be a disruptive method of imaging with its low power, low profile, and non‐invasive nature.

Subjects

MeSH terms (MEDLINE)

RadiometryPhantoms, ImagingX-RaysMonte Carlo Method

Authors and institutions

  • Department of Radiation Oncology, Dana Farber Cancer Institute and Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Radiation Oncology, Dana Farber Cancer Institute, Boston, Massachusetts, USA.
  • Department of Physics and Applied Physics, University of Massachusetts Lowell, Lowell, Massachusetts, USA.

Funding

  • 2023 Summer Undergraduate Fellowship Program

Cite

APA

Rajapakse, A., Outwater, C., Brivio, D., Sajo, E., & Zygmanski, P. (2025). Remote sensing of high energy particle current generated by megavoltage x‐rays. Medical Physics. https://doi.org/10.1002/mp.17756

Vancouver

Rajapakse A, Outwater C, Brivio D, Sajo E, Zygmanski P. Remote sensing of high energy particle current generated by megavoltage x‐rays. Medical Physics. 2025. doi:10.1002/mp.17756

BibTeX
@article{Rajapakse2025,
  author = {Rajapakse, Arith and Outwater, Coral and Brivio, Davide and Sajo, Erno and Zygmanski, Piotr},
  title = {Remote sensing of high energy particle current generated by megavoltage x‐rays},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17756}
}
Start for free →