Fachartikel in der Zeitschrift Medical Physics, 2024. Verfasst von Rodrigo T Massera und 2 weiteren Autor:innen. Beteiligte Einrichtung: Universidade Estadual de Campinas (UNICAMP), Instituto de Física Gleb Wataghin, Campinas, São Paulo, Brazil. Hauptthemen laut MEDLINE: Radiometry, Mammography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), Conselho Nacional de Desenvolvimento Científico e Tecnológico, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

X‐ray breast imaging modalities are commonly employed for breast cancer detection, from screening programs to diagnosis. Thus, dosimetry studies are important for quality control and risk estimation since ionizing radiation is used.

Purpose

To perform multiscale dosimetry assessments for different breast imaging modalities and for a variety of breast sizes and compositions. The first part of our study is focused on macroscopic scales (down to millimeters).

Methods

Nine anthropomorphic breast phantoms with a voxel resolution of 0.5 mm were computationally generated using the BreastPhantom software, representing three breast sizes with three distinct values of volume glandular fraction (VGF) for each size. Four breast imaging modalities were studied: digital mammography (DM), contrast‐enhanced digital mammography (CEDM), digital breast tomosynthesis (DBT) and dedicated breast computed tomography (BCT). Additionally, the impact of tissue elemental compositions from two databases were compared. Monte Carlo (MC) simulations were performed with the MC‐GPU code to obtain the 3D glandular dose distribution (GDD) for each case considered with the mean glandular dose (MGD) fixed at 4 mGy (to facilitate comparisons).

Results

The GDD within the breast is more uniform for CEDM and BCT compared to DM and DBT. For large breasts and high VGF, the ratio between the minimum/maximum glandular dose to MGD is 0.12/4.02 for DM and 0.46/1.77 for BCT; the corresponding results for a small breast and low VGF are 0.35/1.98 (DM) and 0.63/1.42 (BCT). The elemental compositions of skin, adipose and glandular tissue have a considerable impact on the MGD, with variations up to 30% compared to the baseline. The inclusion of tissues other than glandular and adipose within the breast has a minor impact on MGD, with differences below 2%. Variations in the final compressed breast thickness alter the shape of the GDD, with a higher compression resulting in a more uniform GDD.

Conclusions

For a constant MGD, the GDD varies with imaging modality and breast compression. Elemental tissue compositions are an important factor for obtaining MGD values, being a source of systematic uncertainties in MC simulations and, consequently, in breast dosimetry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiometryMammographyX-RaysMonte Carlo MethodPhantoms, ImagingRadiation Dosage

Stichwörter der Autor:innen

Monte Carlobreast CTcontrast enhanced digital mammographydigital breast tomosynthesisdigital mammographyradiation dosimetry

Autor:innen und Institutionen

  • Universidade Estadual de Campinas (UNICAMP), Instituto de Física Gleb Wataghin, Campinas, São Paulo, Brazil.
  • Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University, Ottawa, Ontario, Canada.

Förderung

  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
  • Fundo de apoio ao ensino, pesquisa e Extensão da UNICAMP
  • Emerging leaders of the Americas program of the Government of Canada
  • Natural Sciences and Engineering Research Council of Canada
  • Canada Research Charis

Zitieren

APA

Massera, R. T., Tomal, A., & Thomson, R. M. (2024). Multiscale Monte Carlo simulations for dosimetry in x‐ray breast imaging: Part I ‐ Macroscopic scales. Medical Physics. https://doi.org/10.1002/mp.16910

Vancouver

Massera RT, Tomal A, Thomson RM. Multiscale Monte Carlo simulations for dosimetry in x‐ray breast imaging: Part I ‐ Macroscopic scales. Medical Physics. 2024. doi:10.1002/mp.16910

BibTeX
@article{Massera2024,
  author = {Massera, Rodrigo T and Tomal, Alessandra and Thomson, Rowan M},
  title = {Multiscale Monte Carlo simulations for dosimetry in x‐ray breast imaging: Part I ‐ Macroscopic scales},
  journal = {Medical Physics},
  year = {2024},
  doi = {10.1002/mp.16910}
}
Kostenlos starten →