Energy-based H p (3) measurement using solid-state detector
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncad153 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Nao Ichikawa und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Faculty of Health Science, Kobe Tokiwa University, 2-6-2 Otani-cho, Nagata-ku, Kobe, Hyogo 653-0838, Japan. Hauptthemen laut MEDLINE: Radiometry. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
This study aimed to develop an energy-based Hp(3) measurement method using a solid-state detector (SSD). Incident and entrance surface air kerma were measured using an ionization chamber placed free-in-air and in front of an anthropomorphic or slab phantom. Subsequently, three SSDs were placed free-in-air, and half-value layer and readings were obtained. After measurements, an X-ray beam quality correction factor $\left ({{k}}_{{Q},{{Q}}_{\mathbf{0}}}^{{SSD}}\right)$, backscatter factor (BSF) and conversion factor from incident air kerma to Hp(3) (C3) were determined. Then, the incident air kerma by SSD $\left ({{K}}_{{a},{i}}^{{SSD}}\right )$, Hp(3) and Hp(3)/${{K}}_{{a},{i}}^{{SSD}}$ were calculated. The ${{k}}_{{Q},{{Q}}_{\mathbf{0}}}^{{SSD}}$ was almost consistent for all SSDs. The C3 and BSF were found to increase as tube potential increased. The Hp(3)/${{K}}_{{a},{i}}^{{SSD}}$ calculated with the anthropomorphic and slab phantoms were consistent within 2.1% and 2.6% for all SSDs, respectively. This method improves the energy dependence of Hp(3) measurement and can estimate the Hp(3) measurement error for dedicated Hp(3) dosemeters.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiological Technology, Faculty of Health Science, Kobe Tokiwa University, 2-6-2 Otani-cho, Nagata-ku, Kobe, Hyogo 653-0838, Japan.
- Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan.
- Department of Quantum Medical Technology, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan.
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima 960-1295, Japan.
- Department of Radiation Oncology, Shiga General Hospital, 5-4-30 Moriyama, Moriyama, Shiga 524-0022, Japan.
- Office of Strategy and Planning, Tokyo Institute of Technology, 2-12-1 Ohkayama, Meguro-ku, Tokyo 152-8550, Japan.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Ichikawa, N., Matsubara, K., Fukuda, A., Hayashi, T., Takamatsu, K., & Kuramoto, T. (2023). Energy-based H p (3) measurement using solid-state detector. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad153
Vancouver
Ichikawa N, Matsubara K, Fukuda A, Hayashi T, Takamatsu K, Kuramoto T. Energy-based H p (3) measurement using solid-state detector. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad153
BibTeX
@article{Ichikawa2023,
author = {Ichikawa, Nao and Matsubara, Kosuke and Fukuda, Atsushi and Hayashi, Takuma and Takamatsu, Kunihiko and Kuramoto, Taku},
title = {Energy-based H p (3) measurement using solid-state detector},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncad153}
}
EUVIMED