EUVIMEDDescubrir EUVIMED
Open access · CC BY-NC-ND 4.0

Electron beam monitoring of a modified conventional medical accelerator with a portable current transformer system traceable to primary electrical standards

James Renaud, Bryan Richard Muir, Andrew Williams, Malcolm McEwen

Medical Physics · 2025

DOI: 10.1002/mp.17653 ↗

At a glance

Journal article in Medical Physics, 2025. Written by James Renaud and 3 co-authors. Institution: Metrology Research Centre, National Research Council Canada, Ottawa, Ontario, Canada. Major MEDLINE topics: Particle Accelerators, Electrons, Radiometry. Cited 1 times so far (Crossref); 24 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Background

Ultra‐high dose rate radiotherapy (UHDR) delivers therapeutic doses at rates >40 Gy/s in a fraction of a second, aiming to enhance the therapeutic ratio through the FLASH effect. The substantial increase in UHDR beam current poses serious challenges for conventional active dosimeters. Integrating current transformers (ICT) offer a nondestructive solution for accurate monitoring, enabling the type of fast transient readout that will be crucial for UHDR treatment verification.

Purpose

The aim of this study is to build and characterize a clinically deployable ICT system and to develop an accurate calibration methodology for absolute charge determination that is traceable to primary electrical standards.

Methods

The ICT was constructed from a Super MuMetal ® toroid, and its secondary winding was made from 50 Ω coaxial cable. A 3D‐printed case with an internal conductive coating shields the toroid assembly from interference. The ICT readout involves a custom differential amplifier and a commercial flash analog‐to‐digital converter. The system was calibrated using a bespoke sub‐µs current pulser in the range of (2 to 16) mA, which itself is traceable to electrical standards via an in‐house built electrometer with a calibrated feedback capacitor. The performance of the ICT was evaluated as a milliampere‐scale beam monitor against concurrent absorbed dose graphite calorimetry irradiation measurements acquired on a specially tuned medical accelerator for UHDR delivery.

Results

The ICT responses for nominal test pulses, generated by a function generator and a current pulser, exhibited accurate reproduction of rise and fall times within the 1 ns sampling frequency. A systematic droop effect of 0.6(1)%/µs was observed but is accounted for through the calibration chain. The calibration of the current pulser exhibited a repeatability typically better than 0.05%, with a slowly‐varying leakage that can be subtracted using a linear regression of the leakage current. The ICT charge calibration demonstrated a repeatability in the range of (0.5 to < 0.05)% for charge per pulse values in the range of (0.5 to 50) nC, respectively. The ICT response showed a strong linear relationship (adj‐R 2 = 0.99997) to charge per pulse. The in‐beam comparison with a graphite calorimeter demonstrated the effectiveness of the ICT as an online beam monitor, independent of pulse repetition frequency in the range of (25 to 200) Hz, reducing the mean excess (i.e., independent of accelerator output) calorimeter variation to 0.3% (0.1% standard error on the mean).

Conclusions

This work demonstrates the feasibility of accurately calibrating the ICT in terms of absolute charge and applying it as a clinically deployable monitoring system of mA‐scale electron beams delivered by a medical accelerator.

Subjects

MeSH terms (MEDLINE)

Particle AcceleratorsElectronsRadiometryCalibrationRadiotherapy Dosage

Author keywords

FLASHUHDRbeam current monitorcalorimetrycurrent transformer

Authors and institutions

  • Metrology Research Centre, National Research Council Canada, Ottawa, Ontario, Canada.
  • Wellington Blood and Cancer Centre, Medical Physics, Wellington, New Zealand.

Cite

APA

Renaud, J., Muir, B. R., Williams, A., & McEwen, M. (2025). Electron beam monitoring of a modified conventional medical accelerator with a portable current transformer system traceable to primary electrical standards. Medical Physics. https://doi.org/10.1002/mp.17653

Vancouver

Renaud J, Muir BR, Williams A, McEwen M. Electron beam monitoring of a modified conventional medical accelerator with a portable current transformer system traceable to primary electrical standards. Medical Physics. 2025. doi:10.1002/mp.17653

BibTeX
@article{Renaud2025,
  author = {Renaud, James and Muir, Bryan Richard and Williams, Andrew and McEwen, Malcolm},
  title = {Electron beam monitoring of a modified conventional medical accelerator with a portable current transformer system traceable to primary electrical standards},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.17653}
}
Start for free →