EUVIMEDObjevte EUVIMED
Open access · CC BY 4.0

Open‐source hardware and software for the measurement, characterization, reporting, and correction of geometric distortion in MRI

Brendan M Whelan, Paul Z Y Liu, Shanshan Shan, David E J Waddington, Bin Dong, Michael G Jameson, Paul J Keall

Medical Physics · 2024-11 · 51 (11) · 8399-8410

DOI: 10.1002/mp.17342 ↗

At a glance

Journal article in Medical Physics, published online on 2024-08-07. Written by Brendan M Whelan and 6 co-authors. Institution: Image-X Institute, School of Health Sciences, University of Sydney, Sydney, NSW, Australia. Major MEDLINE topics: Magnetic Resonance Imaging, Software, Phantoms, Imaging, Image Processing, Computer-Assisted. Cited 5 times so far (Crossref); 39 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Geometric distortion is a serious problem in MRI, particularly in MRI guided therapy. A lack of affordable and adaptable tools in this area limits research progress and harmonized quality assurance.

Purpose

To develop and test a suite of open‐source hardware and software tools for the measurement, characterization, reporting, and correction of geometric distortion in MRI.

Methods

An open‐source python library was developed, comprising modules for parametric phantom design, data processing, spherical harmonics, distortion correction, and interactive reporting. The code was used to design and manufacture a distortion phantom consisting of 618 oil filled markers covering a sphere of radius 150 mm. This phantom was imaged on a CT scanner and a novel split‐bore 1.0 T MRI magnet. The CT images provide distortion‐free dataset. These data were used to test all modules of the open‐source software.

Results

All markers were successfully extracted from all images. The distorted MRI markers were mapped to undistorted CT data using an iterative search approach. Spherical harmonics reconstructed the fitted gradient data to 1.0 ± 0.6% of the input data. High resolution data were reconstructed via spherical harmonics and used to generate an interactive report. Finally, distortion correction on an independent data set reduced distortion inside the DSV from 5.5 ± 3.1 to 1.6 ± 0.8 mm.

Conclusion

Open‐source hardware and software for the measurement, characterization, reporting, and correction of geometric distortion in MRI have been developed. The utility of these tools has been demonstrated via their application on a novel 1.0 T split bore magnet.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingSoftwarePhantoms, ImagingImage Processing, Computer-Assisted

Author keywords

MRIdistortionopen‐source

Authors and institutions

  • Image-X Institute, School of Health Sciences, University of Sydney, Sydney, NSW, Australia.
  • Ingham Institute for Applied Medical Research, Liverpool, NSW, Australia.
  • GenesisCare, Sydney, NSW, Australia.
  • St Vincent's Clinical School, Faculty of Medicine, University NSW, Sydney, Australia.

Cite

APA

Whelan, B. M., Liu, P. Z. Y., Shan, S., Waddington, D. E. J., Dong, B., Jameson, M. G., & Keall, P. J. (2024). Open‐source hardware and software for the measurement, characterization, reporting, and correction of geometric distortion in MRI. Medical Physics, 51(11), 8399-8410. https://doi.org/10.1002/mp.17342

Vancouver

Whelan BM, Liu PZY, Shan S, Waddington DEJ, Dong B, Jameson MG, et al. Open‐source hardware and software for the measurement, characterization, reporting, and correction of geometric distortion in MRI. Medical Physics. 2024;51(11):8399-8410. doi:10.1002/mp.17342

BibTeX
@article{Whelan2024,
  author = {Whelan, Brendan M and Liu, Paul Z Y and Shan, Shanshan and Waddington, David E J and Dong, Bin and Jameson, Michael G and Keall, Paul J},
  title = {Open‐source hardware and software for the measurement, characterization, reporting, and correction of geometric distortion in MRI},
  journal = {Medical Physics},
  year = {2024},
  volume = {51},
  number = {11},
  pages = {8399--8410},
  doi = {10.1002/mp.17342}
}
Start for free →