Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von James C Korte und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC, 3000, Australia. James.Korte@petermac.org. Hauptthemen laut MEDLINE: Software, Diffusion Magnetic Resonance Imaging, Magnetic Resonance Imaging, Multiparametric Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Melbourne.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To validate the automated analysis of magnetic resonance imaging (MRI) diffusion phantoms with an updated version of the magnetic resonance biomarker assessment software (MR-BIAS), an open-source tool initially developed for the analysis of MRI relaxometry phantoms. Materials and methods The updated MR-BIAS was validated against two published diffusion weighted MRI datasets: (i) a single-site study ( n = 48) was used for validation of apparent diffusion coefficients (ADC) and to identify optimal region of interest (ROI) selection, and (ii) a multi-centre multi-vendor study including diffusion imaging from a shared benchmark protocol ( n = 49) and site-specific protocols ( n = 43). ADC analysis compared both datasets with ROIs manually matched to the original studies, and with automatically detected optimal ROIs.

Results

MR-BIAS ADC values were statistically equivalent ( p < 0.05) to original studies within tolerances (manual ROI, automatic ROI) for the single-site study (± 0.01, ± 6 μm 2 /s) and for the multi-vendor study for benchmark (± 4, ± 7 μm 2 /s) and site-specific (± 3, ± 6 μm 2 /s) protocols. The optimal ROI was a central cylinder (height = 10mm, diamete r = 10mm). MR-BIAS ADC summary metrics were comparable to those of the original studies.

Discussion

MR-BIAS can automatically and accurately perform ADC analysis of diffusion phantoms, making the software suitable for the quality assurance of multi-centre studies of multi-parametric MRI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SoftwareDiffusion Magnetic Resonance ImagingMagnetic Resonance ImagingMultiparametric Magnetic Resonance ImagingPhantoms, ImagingHumansReproducibility of ResultsImage Processing, Computer-AssistedBiomarkersImage Interpretation, Computer-AssistedAlgorithmsQuality Assurance, Health CareQuality Control

Stichwörter der Autor:innen

Diffusion magnetic resonance imaging (D038524)Imaging (D019047)Multiparametric magnetic resonance imaging (D000081364)PhantomsSoftware [open source software] (D012984)Software validation (D012986)

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC, 3000, Australia. James.Korte@petermac.org.
  • Department of Biomedical Engineering, The University of Melbourne, Melbourne, Australia. James.Korte@petermac.org.
  • Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC, 3000, Australia.
  • School of Science, RMIT University, Melbourne, Australia.
  • Monash Imaging, Monash Health, Melbourne, Australia.
  • Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia.

Förderung

  • University of Melbourne

Zitieren

APA

Korte, J. C., Norris, S. A., Carr, M. E., Holloway, L., Cahoon, G. D., Neijndorff, B., van Houdt, P., & Franich, R. (2025). Open-source quality assurance for multi-parametric MRI: a diffusion analysis update for the magnetic resonance biomarker assessment software (MR-BIAS). Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01252-4

Vancouver

Korte JC, Norris SA, Carr ME, Holloway L, Cahoon GD, Neijndorff B, et al. Open-source quality assurance for multi-parametric MRI: a diffusion analysis update for the magnetic resonance biomarker assessment software (MR-BIAS). Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01252-4

BibTeX
@article{Korte2025,
  author = {Korte, James C and Norris, Stanley A and Carr, Madeline E and Holloway, Lois and Cahoon, Glenn D and Neijndorff, Ben and van Houdt, Petra and Franich, Rick},
  title = {Open-source quality assurance for multi-parametric MRI: a diffusion analysis update for the magnetic resonance biomarker assessment software (MR-BIAS)},
  journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
  year = {2025},
  doi = {10.1007/s10334-025-01252-4}
}
Kostenlos starten →