Open-source quality assurance for multi-parametric MRI: a diffusion analysis update for the magnetic resonance biomarker assessment software (MR-BIAS)
Magnetic Resonance Materials in Physics, Biology and Medicine · 2025
DOI: 10.1007/s10334-025-01252-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance Materials in Physics, Biology and Medicine, 2025. Verfasst von James C Korte und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC, 3000, Australia. James.Korte@petermac.org. Hauptthemen laut MEDLINE: Software, Diffusion Magnetic Resonance Imaging, Magnetic Resonance Imaging, Multiparametric Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Melbourne.
Abstract (Originalsprache)
Objective
To validate the automated analysis of magnetic resonance imaging (MRI) diffusion phantoms with an updated version of the magnetic resonance biomarker assessment software (MR-BIAS), an open-source tool initially developed for the analysis of MRI relaxometry phantoms. Materials and methods The updated MR-BIAS was validated against two published diffusion weighted MRI datasets: (i) a single-site study ( n = 48) was used for validation of apparent diffusion coefficients (ADC) and to identify optimal region of interest (ROI) selection, and (ii) a multi-centre multi-vendor study including diffusion imaging from a shared benchmark protocol ( n = 49) and site-specific protocols ( n = 43). ADC analysis compared both datasets with ROIs manually matched to the original studies, and with automatically detected optimal ROIs.
Results
MR-BIAS ADC values were statistically equivalent ( p < 0.05) to original studies within tolerances (manual ROI, automatic ROI) for the single-site study (± 0.01, ± 6 μm 2 /s) and for the multi-vendor study for benchmark (± 4, ± 7 μm 2 /s) and site-specific (± 3, ± 6 μm 2 /s) protocols. The optimal ROI was a central cylinder (height = 10mm, diamete r = 10mm). MR-BIAS ADC summary metrics were comparable to those of the original studies.
Discussion
MR-BIAS can automatically and accurately perform ADC analysis of diffusion phantoms, making the software suitable for the quality assurance of multi-centre studies of multi-parametric MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC, 3000, Australia. James.Korte@petermac.org.
- Department of Biomedical Engineering, The University of Melbourne, Melbourne, Australia. James.Korte@petermac.org.
- Department of Physical Sciences, Peter MacCallum Cancer Centre, 305 Grattan Street, Melbourne, VIC, 3000, Australia.
- School of Science, RMIT University, Melbourne, Australia.
- Monash Imaging, Monash Health, Melbourne, Australia.
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia.
Förderung
- University of Melbourne
Zitieren
APA
Korte, J. C., Norris, S. A., Carr, M. E., Holloway, L., Cahoon, G. D., Neijndorff, B., van Houdt, P., & Franich, R. (2025). Open-source quality assurance for multi-parametric MRI: a diffusion analysis update for the magnetic resonance biomarker assessment software (MR-BIAS). Magnetic Resonance Materials in Physics, Biology and Medicine. https://doi.org/10.1007/s10334-025-01252-4
Vancouver
Korte JC, Norris SA, Carr ME, Holloway L, Cahoon GD, Neijndorff B, et al. Open-source quality assurance for multi-parametric MRI: a diffusion analysis update for the magnetic resonance biomarker assessment software (MR-BIAS). Magnetic Resonance Materials in Physics, Biology and Medicine. 2025. doi:10.1007/s10334-025-01252-4
BibTeX
@article{Korte2025,
author = {Korte, James C and Norris, Stanley A and Carr, Madeline E and Holloway, Lois and Cahoon, Glenn D and Neijndorff, Ben and van Houdt, Petra and Franich, Rick},
title = {Open-source quality assurance for multi-parametric MRI: a diffusion analysis update for the magnetic resonance biomarker assessment software (MR-BIAS)},
journal = {Magnetic Resonance Materials in Physics, Biology and Medicine},
year = {2025},
doi = {10.1007/s10334-025-01252-4}
}
EUVIMED