Optimising 7T ‐ fMRI for Imaging Regions of Magnetic Susceptibility
Human Brain Mapping · 2026-08 · 47 (11)
DOI: 10.1002/hbm.70621 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, online erschienen am 10.08.2026. Verfasst von Saskia L Frisby und 6 weiteren Autor:innen. Beteiligte Einrichtung: MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain Mapping, Image Processing, Computer-Assisted, Brain. Die Arbeit nennt 94 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council, NIHR Cambridge Biomedical Research Centre.
Abstract (Originalsprache)
The temporal signal‐to‐noise ratio (tSNR) of functional magnetic resonance imaging (fMRI) is particularly poor in ventral anterior temporal and orbitofrontal regions because of B 0 and B 1 + magnetic field inhomogeneity, a problem that is exacerbated at higher field strengths. In this 7T‐fMRI study we compared three methods of improving sensitivity in these areas: parallel transmit, which uses multiple transmit elements, controlled independently, to homogenise the flip angle experienced by the tissue; multi‐echo, which entails collection of multiple volumes at different echo times following a single radiofrequency pulse; and multiband, in which multiple slices are acquired simultaneously. We found that parallel transmit and multi‐echo increased the magnitude of the BOLD signal change, but only multi‐echo increased BOLD magnitude in areas prone to susceptibility artefacts. Multiband and denoising of multi‐echo data with independent components analysis (ICA) both improved precision of GLM fit. Exploratory results suggested that multi‐echo and ICA denoising can both benefit multivariate analyses. In conclusion, a multi‐echo, multiband sequence improved fMRI quality in areas prone to susceptibility artefacts while maintaining sensitivity across the whole brain. We recommend this approach for studies investigating the functional roles of ventral temporal and orbitofrontal regions with 7T fMRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- MRC Cognition and Brain Sciences Unit, University of Cambridge, Cambridge, UK.
- Wolfson Brain Imaging Centre, University of Cambridge, Cambridge, UK.
- Department of Psychology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Institute of Cognitive Neuroscience, University College London, London, UK.
ORCID-Profile: Saskia L Frisby, Marta M Correia, Minghao Zhang, Christopher T Rodgers, Timothy T Rogers, Matthew A Lambon Ralph, Ajay D Halai
Förderung
- Medical Research Council
- NIHR Cambridge Biomedical Research Centre
Zitieren
APA
Frisby, S. L., Correia, M. M., Zhang, M., Rodgers, C. T., Rogers, T. T., Lambon Ralph, M. A., & Halai, A. D. (2026). Optimising 7T ‐ fMRI for Imaging Regions of Magnetic Susceptibility. Human Brain Mapping, 47(11). https://doi.org/10.1002/hbm.70621
Vancouver
Frisby SL, Correia MM, Zhang M, Rodgers CT, Rogers TT, Lambon Ralph MA, et al. Optimising 7T ‐ fMRI for Imaging Regions of Magnetic Susceptibility. Human Brain Mapping. 2026;47(11). doi:10.1002/hbm.70621
BibTeX
@article{Frisby2026,
author = {Frisby, Saskia L and Correia, Marta M and Zhang, Minghao and Rodgers, Christopher T and Rogers, Timothy T and Lambon Ralph, Matthew A and Halai, Ajay D},
title = {Optimising 7T ‐ fMRI for Imaging Regions of Magnetic Susceptibility},
journal = {Human Brain Mapping},
year = {2026},
volume = {47},
number = {11},
doi = {10.1002/hbm.70621}
}
EUVIMED