Correction of Physiological Artifacts in Multi‐Echo fMRI Data—Evaluation of Possible RETROICOR Implementations
Human Brain Mapping · 2025
DOI: 10.1002/hbm.70264 ↗Kurz gefasst
Fachartikel in der Zeitschrift Human Brain Mapping, 2025. Verfasst von Anežka Kovářová und 1 weiteren Autor:innen. Beteiligte Einrichtung: CEITEC - Central European Institute of Technology, Masaryk University, Brno, Czech Republic. Hauptthemen laut MEDLINE: Artifacts, Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministerstvo Školství, Mládeže a Tělovýchovy, Grantová Agentura České Republiky.
Abstract (Originalsprache)
The study evaluates the efficacy of RETROICOR (Retrospective Image Correction) in mitigating physiological artifacts within multi‐echo (ME) fMRI data. Two RETROICOR implementations were compared: applying corrections to individual echoes (RTC_ind) versus composite multi‐echo data (RTC_comp). Data from 50 healthy participants were collected using diverse acquisition parameters, including multiband acceleration factors and varying flip angles, on a Siemens Prisma 3T scanner. Key metrics such as temporal signal‐to‐noise ratio (tSNR), signal fluctuation sensitivity (SFS), and variance of residuals demonstrated improved data quality in both RETROICOR models, particularly in moderately accelerated runs (multiband factors 4 and 6) with lower flip angles (45°). Differences between RTC_ind and RTC_comp were minimal, suggesting both methods are viable for practical applications. While the highest acceleration (multiband factor 8) degraded data quality, RETROICOR's compatibility with faster acquisition sequences was confirmed. These findings underscore the importance of optimizing acquisition parameters and noise correction techniques for reliable fMRI investigations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- CEITEC - Central European Institute of Technology, Masaryk University, Brno, Czech Republic.
- First Department of Neurology, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
ORCID-Profile: Anežka Kovářová, Michal Mikl
Förderung
- Ministerstvo Školství, Mládeže a Tělovýchovy
- Grantová Agentura České Republiky
Zitieren
APA
Kovářová, A., & Mikl, M. (2025). Correction of Physiological Artifacts in Multi‐Echo fMRI Data—Evaluation of Possible RETROICOR Implementations. Human Brain Mapping. https://doi.org/10.1002/hbm.70264
Vancouver
Kovářová A, Mikl M. Correction of Physiological Artifacts in Multi‐Echo fMRI Data—Evaluation of Possible RETROICOR Implementations. Human Brain Mapping. 2025. doi:10.1002/hbm.70264
BibTeX
@article{Kovov2025,
author = {Kovářová, Anežka and Mikl, Michal},
title = {Correction of Physiological Artifacts in Multi‐Echo fMRI Data—Evaluation of Possible RETROICOR Implementations},
journal = {Human Brain Mapping},
year = {2025},
doi = {10.1002/hbm.70264}
}
EUVIMED