Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2025. Verfasst von Usha D Nagaraj und 5 weiteren Autor:innen. Beteiligte Einrichtung: Cincinnati Children's Hospital Medical Center, University of Cincinnati Department of Radiology, 3333 Burnet Avenue, Cincinnati, OH 45229-3026, Unite…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Neural Networks, Computer, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Cincinnati Children's Hospital Medical Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Synthetic MRI (SyMRI) is a technique used to estimate tissue properties and generate multiple MR sequence contrasts from a single acquisition. However, image quality can be suboptimal. PURPOSE: To evaluate a neural network approach using artificial intelligence-based direct contrast synthesis (AI-DCS) of the multi-contrast weighted images to improve image quality. MATERIALS AND METHODS: This prospective, IRB approved study enrolled 50 pediatric patients undergoing clinical brain MRI. In addition to the standard of care (SOC) clinical protocol, 2D multi-delay multi-echo (MDME) sequence was obtained. SOC 3D T1-weighted (T1W), 2D T2-weighted (T2W) and 2D T2W fluid-attenuated inversion recovery (FLAIR) images from 35 patients were used to train a neural network generating synthetic T1W, T2W, and FLAIR images. Quantitative analysis of grey matter (GM) and white matter (WM) apparent signal to noise (aSNR) and grey-white matter (GWM) apparent contrast to noise (aCNR) ratios was performed. RESULTS: 8 patients were evaluated. When compared to SyMRI, T1W AI-DCS had better overall image quality, reduced noise/artifacts, and better subjective SNR in 100 % (16/16) of evaluations. When compared to SyMRI, T2W AI-DCS overall image quality and diagnostic confidence was better in 93.8 % (15/16) and 87.5 % (14/16) of evaluations, respectively. When compared to SyMRI, FLAIR AI-DCS was better in 93.8 % (15/16) of evaluations in overall image quality and in 100 % (16/16) of evaluations for noise/artifacts and subjective SNR. Quantitative analysis revealed higher WM aSNR compared with SyMRI (p < 0.05) for T1W, T2W and FLAIR. CONCLUSION: AI-DCS demonstrates better overall image quality than SyMRI on T1W, T2W and FLAIR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainNeural Networks, ComputerImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedHumansChildFemaleMaleProspective StudiesChild, PreschoolAdolescentSignal-To-Noise RatioInfantWhite MatterArtifactsGray MatterArtificial Intelligence

Stichwörter der Autor:innen

Artificial intelligencePediatric brainSynthetic MRI

Autor:innen und Institutionen

  • Cincinnati Children's Hospital Medical Center, University of Cincinnati Department of Radiology, 3333 Burnet Avenue, Cincinnati, OH 45229-3026, United States; University of Cincinnati Department of Radiology, 222 Piedmo…
  • Philips Innovative Technologies, Röntgenstr. 24-26, 22335 Hamburg, Germany. Electronic address: Jakob.meineke@philips.com.
  • Philips Innovative Technologies, Röntgenstr. 24-26, 22335 Hamburg, Germany. Electronic address: sriwasaa@ucmail.uc.edu.
  • Philips Innovative Technologies, Röntgenstr. 24-26, 22335 Hamburg, Germany. Electronic address: mariya.doneva@philips.com.

Förderung

  • Cincinnati Children's Hospital Medical Center

Zitieren

APA

Nagaraj, U. D., Meineke, J., Sriwastwa, A., Tkach, J. A., Leach, J. L., & Doneva, M. (2025). Evaluation of synthetic images derived from a neural network in pediatric brain magnetic resonance imaging. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2025.110427

Vancouver

Nagaraj UD, Meineke J, Sriwastwa A, Tkach JA, Leach JL, Doneva M. Evaluation of synthetic images derived from a neural network in pediatric brain magnetic resonance imaging. Magnetic Resonance Imaging. 2025. doi:10.1016/j.mri.2025.110427

BibTeX
@article{Nagaraj2025,
  author = {Nagaraj, Usha D and Meineke, Jakob and Sriwastwa, Aakanksha and Tkach, Jean A and Leach, James L and Doneva, Mariya},
  title = {Evaluation of synthetic images derived from a neural network in pediatric brain magnetic resonance imaging},
  journal = {Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1016/j.mri.2025.110427}
}
Kostenlos starten →