EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T

Guoxiang Liu iD, Takashi Ueguchi, Seiji Ogawa

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.30569 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Guoxiang Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Brain Function Analysis and Imaging Laboratory, Center for Information and Neural Networks, Advanced ICT Research Institute, National Institute of In…. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Image Processing, Computer-Assisted, Brain, Magnetic Resonance Imaging. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Japan Society for the Promotion of Science (JSPS) Grant-in-Aid for Scientific Research "KAKENHI", Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Isotropic submillimeter high‐resolution functional MRI (fMRI) facilitates noninvasive investigation of neuronal activities at the mesoscale level, including cortical columns and laminae. However, the task‐evoked functional activity becomes less detectable when using single‐shot echo planar imaging (EPI) with parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA), owing to a reduction in temporal signal‐to‐noise ratio (tSNR). Although conventional multishot EPI (msEPI) enhances tSNR, it reduces temporal resolution, making it less suitable for fMRI studies involving short‐duration stimuli. To overcome this problem, a novel msEPI‐based fMRI acquisition and reconstruction method, called block‐interleaved segmented EPI (BISEPI), was proposed.

Methods

This technique uses timing information of a block design paradigm during acquisition and reconstruction to preserve both temporal resolution and tSNR. Furthermore, a k‐space‐based motion correction method is incorporated to mitigate head motion artifacts.

Results

Results from human studies showed that the proposed method reduced g‐factor penalties typically observed in GRAPPA‐accelerated EPI. It provided high tSNR, improved motion robustness, and enhanced sensitivity to blood oxygen level–dependent signal responses.

Conclusion

The proposed method circumvents both conventional msEPI‐related and GRAPPA‐related problems and enables the detection of blood oxygen level–dependent signal responses at submillimeter spatial resolution. It is effective for paradigms using short‐duration, low‐power stimuli at 0.7‐mm isotropic resolution, and standard‐power stimuli at 0.4‐mm isotropic resolution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echo-Planar ImagingImage Processing, Computer-AssistedBrainMagnetic Resonance ImagingBrain MappingHumansSignal-To-Noise RatioAlgorithmsArtifactsAdultMaleFemale

Stichwörter der Autor:innen

BOLDEPIimage acquisition and reconstructionk‐space segmentationsubmillimeter high‐resolution fMRIultrahigh magnetic field

Autor:innen und Institutionen

  • Brain Function Analysis and Imaging Laboratory, Center for Information and Neural Networks, Advanced ICT Research Institute, National Institute of Information and Communications Technology, Suita, Osaka, Japan.
  • Graduate School of Frontier Biosciences, The University of Osaka, Suita, Osaka, Japan.
  • Kobe University Graduate School of Health Sciences, Suma, Kobe, Japan.
  • The University of Osaka Graduate School of Medicine, Suita, Osaka, Japan.
  • Kansei Fukushi Research Institute, Tohoku Fukushi University, Sendai, Japan.

ORCID-Profile: Guoxiang Liu

Förderung

  • Japan Society for the Promotion of Science (JSPS) Grant-in-Aid for Scientific Research "KAKENHI"
  • Japan Society for the Promotion of Science

Zitieren

APA

Liu, G., Ueguchi, T., & Ogawa, S. (2026). Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30569

Vancouver

Liu G, Ueguchi T, Ogawa S. Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.30569

BibTeX
@article{Liu2026,
  author = {Liu, Guoxiang and Ueguchi, Takashi and Ogawa, Seiji},
  title = {Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.30569}
}
Kostenlos starten →