Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.30569 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Guoxiang Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Brain Function Analysis and Imaging Laboratory, Center for Information and Neural Networks, Advanced ICT Research Institute, National Institute of In…. Hauptthemen laut MEDLINE: Echo-Planar Imaging, Image Processing, Computer-Assisted, Brain, Magnetic Resonance Imaging. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Japan Society for the Promotion of Science (JSPS) Grant-in-Aid for Scientific Research "KAKENHI", Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Purpose
Isotropic submillimeter high‐resolution functional MRI (fMRI) facilitates noninvasive investigation of neuronal activities at the mesoscale level, including cortical columns and laminae. However, the task‐evoked functional activity becomes less detectable when using single‐shot echo planar imaging (EPI) with parallel imaging techniques such as generalized autocalibrating partially parallel acquisitions (GRAPPA), owing to a reduction in temporal signal‐to‐noise ratio (tSNR). Although conventional multishot EPI (msEPI) enhances tSNR, it reduces temporal resolution, making it less suitable for fMRI studies involving short‐duration stimuli. To overcome this problem, a novel msEPI‐based fMRI acquisition and reconstruction method, called block‐interleaved segmented EPI (BISEPI), was proposed.
Methods
This technique uses timing information of a block design paradigm during acquisition and reconstruction to preserve both temporal resolution and tSNR. Furthermore, a k‐space‐based motion correction method is incorporated to mitigate head motion artifacts.
Results
Results from human studies showed that the proposed method reduced g‐factor penalties typically observed in GRAPPA‐accelerated EPI. It provided high tSNR, improved motion robustness, and enhanced sensitivity to blood oxygen level–dependent signal responses.
Conclusion
The proposed method circumvents both conventional msEPI‐related and GRAPPA‐related problems and enables the detection of blood oxygen level–dependent signal responses at submillimeter spatial resolution. It is effective for paradigms using short‐duration, low‐power stimuli at 0.7‐mm isotropic resolution, and standard‐power stimuli at 0.4‐mm isotropic resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Brain Function Analysis and Imaging Laboratory, Center for Information and Neural Networks, Advanced ICT Research Institute, National Institute of Information and Communications Technology, Suita, Osaka, Japan.
- Graduate School of Frontier Biosciences, The University of Osaka, Suita, Osaka, Japan.
- Kobe University Graduate School of Health Sciences, Suma, Kobe, Japan.
- The University of Osaka Graduate School of Medicine, Suita, Osaka, Japan.
- Kansei Fukushi Research Institute, Tohoku Fukushi University, Sendai, Japan.
ORCID-Profile: Guoxiang Liu
Förderung
- Japan Society for the Promotion of Science (JSPS) Grant-in-Aid for Scientific Research "KAKENHI"
- Japan Society for the Promotion of Science
Zitieren
APA
Liu, G., Ueguchi, T., & Ogawa, S. (2026). Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30569
Vancouver
Liu G, Ueguchi T, Ogawa S. Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.30569
BibTeX
@article{Liu2026,
author = {Liu, Guoxiang and Ueguchi, Takashi and Ogawa, Seiji},
title = {Block‐interleaved segmented echo‐planar imaging for improved activity detection in submillimeter high‐resolution functional MRI at 7 T},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.30569}
}
EUVIMED