EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Benchmarking fMRI Denoising Pipelines

Tianye Zhai iD, Hong Gu iD, Anika Holton, Elanor Chang, Blaise B Frederick iD, Thomas J Ross iD, Yihong Yang iD, Amy C Janes iD

Human Brain Mapping · 2026

DOI: 10.1002/hbm.70561 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Human Brain Mapping, 2026. Verfasst von Tianye Zhai und 7 weiteren Autor:innen. Beteiligte Einrichtung: Neuroimaging Research Branch, Intramural Research Program, National Institute on Drug Abuse, National Institutes of Health, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted, Brain Mapping. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Intramural NIH HHS, Intramural Research Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Functional magnetic resonance imaging (fMRI) is a powerful tool for probing neuronal activity in vivo, but fMRI data are inherently noisy. To mitigate this, a wide range of denoising strategies have been developed, including volume censoring, anatomical component‐based noise correction (aCompCor), ICA‐based methods (e.g., AROMA, FIX), and multi‐echo approaches (e.g., ME‐ICA, tedana). These techniques are often applied in different combinations and have been predominantly evaluated on single‐echo resting‐state fMRI data—typically without incorporating more recent methodological advances known to improve modeling, such as order‐independent “1‐step regression”, modeling temporal autocorrelation (pre‐whitening), and temporal shifting of physiological nuisance regressors. To fill this gap, we used a framework that incorporates these methods and benchmarked a range of denoising pipelines across task and resting‐state, single‐ and multi‐band, and single‐ and multi‐echo fMRI datasets, using different combinations of standard denoising confounds. Pipeline performance was evaluated using temporal signal‐to‐noise ratio (tSNR) and percentage remaining degrees‐of‐freedom (DoF), effectiveness of motion correction, and effectiveness of signal preservation. While pipelines only using ICA were insufficient, those that incorporated physiological nuisance regressors performed well. Additional improvements were observed when temporally shifted physiological regressors were accounted for. Based on these results, we provide recommendations for selecting denoising pipelines and emphasize the need for continued benchmarking as new methods are developed or applied in novel contexts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainImage Processing, Computer-AssistedBrain MappingHumansSignal-To-Noise RatioBenchmarkingArtifacts

Stichwörter der Autor:innen

1‐step regressionfMRI denoising pipelinemulti‐echopre‐whiteningtime‐shifted physiological confounds

Autor:innen und Institutionen

  • Neuroimaging Research Branch, Intramural Research Program, National Institute on Drug Abuse, National Institutes of Health, Baltimore, Maryland, USA.
  • Department of Psychiatry, Harvard University Medical School, Boston, Massachusetts, USA.

ORCID-Profile: Tianye Zhai, Hong Gu, Blaise B Frederick, Thomas J Ross, Yihong Yang, Amy C Janes

Förderung

  • Intramural NIH HHS
  • Intramural Research Program

Zitieren

APA

Zhai, T., Gu, H., Holton, A., Chang, E., Frederick, B. B., Ross, T. J., Yang, Y., & Janes, A. C. (2026). Benchmarking fMRI Denoising Pipelines. Human Brain Mapping. https://doi.org/10.1002/hbm.70561

Vancouver

Zhai T, Gu H, Holton A, Chang E, Frederick BB, Ross TJ, et al. Benchmarking fMRI Denoising Pipelines. Human Brain Mapping. 2026. doi:10.1002/hbm.70561

BibTeX
@article{Zhai2026,
  author = {Zhai, Tianye and Gu, Hong and Holton, Anika and Chang, Elanor and Frederick, Blaise B and Ross, Thomas J and Yang, Yihong and Janes, Amy C},
  title = {Benchmarking fMRI Denoising Pipelines},
  journal = {Human Brain Mapping},
  year = {2026},
  doi = {10.1002/hbm.70561}
}
Kostenlos starten →