EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Polymer‐Based Multiparameter Sensing Integrated Photonic Chip for Health Monitoring

Xiaolin Li, Hongqiang Li iD, Ming Han, Xin Liu, Mingjun Ding, Ziying Niu, Dongyang Liu, Liyuan Yang, Lizhen Zhang, Francisco Hernández-Ramírez, Lu Cao, Enbang Li

Advanced Science · 2026

DOI: 10.1002/advs.76123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, 2026. Verfasst von Xiaolin Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Optoelectronic Detection Technology and Systems, School of Electronics and Information Engineering, Tiangong University, Ti…. Hauptthemen laut MEDLINE: Biosensing Techniques, Polymers, Blood Glucose. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Project of Natural Science Foundation of Tianjin, Key Research and Development Program of Tianjin.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optical sensors are essential in medical diagnostics and detect variations in light intensity, phase, wavelength, polarization, or interference. However, conventional devices face limitations in multiplexing capability, surface functionalization, and integration. Here, we propose a monolithic integrated poly(dimethylsiloxane) (PDMS)/poly(methyl methacrylate) (PMMA) photonic chip that monolithically integrates two photonic waveguide Bragg grating (WBG) blood glucose sensors, a photonic WBG pressure sensor array, four photonic WBG temperature sensors, a photonic Mach–Zehnder modulator (MZM) electrocardiogram (ECG) sensor, and a photonic Mach–Zehnder interferometer (MZI) sweat glucose sensor, together with an on–chip arrayed waveguide grating (AWG) demodulation unit. The experimental results demonstrate that the WBG glucose sensor operates stably from 0 to 2.3 mg/mL, the pressure sensor from 0 to 12 kPa, and the temperature sensor from 35 to 41°C. The MZM ECG sensor achieves a half–wave voltage of 1.6 V, with performance comparable to that of commercial systems. The MZI sweat glucose sensor offers a detection range of 0–0.2 mg/mL, a sensitivity of approximately 9.3595 mW/(mg/mL), and high linearity. With a miniature footprint of approximately 1 cm × 0.5 cm, this work offers a robust on‐chip multiparameter sensing solution, paving the way for next–generation wearable continuous health monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesPolymersBlood GlucoseHumansEquipment DesignMonitoring, PhysiologicDimethylpolysiloxanes

Stichwörter der Autor:innen

Mach–Zehnder modulatorblood glucoseelectrocardiogramintegrated photonic chippressuretemperaturewaveguide Bragg grating

Substanzen

baysilonDimethylpolysiloxanesPolymersBlood Glucose

Autor:innen und Institutionen

  • Tianjin Key Laboratory of Optoelectronic Detection Technology and Systems, School of Electronics and Information Engineering, Tiangong University, Tianjin, China.
  • Shaoxing Keqiao Research Institute of Tiangong University, Shaoxing, China.
  • Tianjin Key Laboratory of Intelligent Control of Electrical Equipment, School of Control Science and Engineering, Tiangong University, Tianjin, China.
  • Engineering Teaching Practice Training Center, Tiangong University, Tianjin, China.
  • School of Chemical Engineering and Technology, Tiangong University, Tianjin, China.
  • School of Innovation and Entrepreneurship, Tiangong University, Tianjin, China.

ORCID-Profile: Hongqiang Li

Förderung

  • National Natural Science Foundation of China
  • Key Project of Natural Science Foundation of Tianjin
  • Key Research and Development Program of Tianjin
  • Open Project of Tianjin Key Laboratory of Optoelectronic Detection Technology and System

Zitieren

APA

Li, X., Li, H., Han, M., Liu, X., Ding, M., Niu, Z., Liu, D., Yang, L., Zhang, L., Hernández-Ramírez, F., Cao, L., & Li, E. (2026). Polymer‐Based Multiparameter Sensing Integrated Photonic Chip for Health Monitoring. Advanced Science. https://doi.org/10.1002/advs.76123

Vancouver

Li X, Li H, Han M, Liu X, Ding M, Niu Z, et al. Polymer‐Based Multiparameter Sensing Integrated Photonic Chip for Health Monitoring. Advanced Science. 2026. doi:10.1002/advs.76123

BibTeX
@article{Li2026,
  author = {Li, Xiaolin and Li, Hongqiang and Han, Ming and Liu, Xin and Ding, Mingjun and Niu, Ziying and Liu, Dongyang and Yang, Liyuan and Zhang, Lizhen and Hernández-Ramírez, Francisco and Cao, Lu and Li, Enbang},
  title = {Polymer‐Based Multiparameter Sensing Integrated Photonic Chip for Health Monitoring},
  journal = {Advanced Science},
  year = {2026},
  doi = {10.1002/advs.76123}
}
Kostenlos starten →