Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms
Biosensors and Bioelectronics · 2025
DOI: 10.1016/j.bios.2025.117656 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Mengmeng Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Process & Energy, Delft University of Technology, Leeghwaterstraat 39, Delft, 2628 CB, The Netherlands. Electronic address: m.zhang-7@t…. Hauptthemen laut MEDLINE: Biosensing Techniques, Lab-On-A-Chip Devices, Microfluidic Analytical Techniques, Blood Glucose. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Delft University of Technology.
Abstract (Originalsprache)
Lateral flow assays (LFAs) are widely favored for on-site analysis due to their simplicity and cost-effectiveness. However, their limited quantitative capabilities constrain them to qualitative testing. In contrast, etalon sensors offer high sensitivity and enable quantitative detection. They operate by producing interference-based optical signals through multiple reflections of light within a cavity formed by two parallel reflective surfaces. This requires a stable optical path length, traditionally limiting their use to smooth substrates. This study presents an integrated separation-sensing microfluidic platform (EtLFA). By fabricating etalons on commercial membranes and evaluating sensor's sensitivity and surface roughness, we determined that membrane surface roughness must meet two criteria - Sa 90% - to support functional etalons. Capillary and permeability remain intact after etalon integration, ensuring membrane's purification performance. We further functionalized the etalon to respond specifically to glucose, to demonstrate the quantitative detection of glucose levels in a mimic blood sample. A glucose-responsive etalon@nylon served as the sensor module, while regenerated cellulose membrane enabled separation. This dual-module configuration filtered PDMS particles mimicking red blood cells and produced a 25 nm shift for 100 mg/dL glucose, enabling linear quantification via portable spectrometry. By incorporating etalon sensor onto rough membrane substrates, our platform transforms conventional LFAs into a quantitative analytical tool, offering novel avenues for enhancing analytical capabilities and broadening the applications of lateral flow assays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Process & Energy, Delft University of Technology, Leeghwaterstraat 39, Delft, 2628 CB, The Netherlands. Electronic address: m.zhang-7@tudelft.nl.
- Department of BioMechanical Engineering, Delft University of Technology, Mekelweg 2, Delft, 2628 CD, The Netherlands; Co van Ledden Hulsebosch - Netherlands Center for Forensic Science and Medicine, Science Park - Build…
- Department of Chemistry, University of Alberta, 11227 Saskatchewan, Edmonton, T6G 2G2, Canada. Electronic address: serpe@ualberta.ca.
- Department of Chemical Engineering, Delft University of Technology, Van der Maasweg 9, Delft, 2629 HZ, The Netherlands. Electronic address: h.bazyar@tudelft.nl.
Förderung
- Delft University of Technology
Zitieren
APA
Zhang, M., Loeve, A. J., Serpe, M. J., & Bazyar, H. (2025). Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117656
Vancouver
Zhang M, Loeve AJ, Serpe MJ, Bazyar H. Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117656
BibTeX
@article{Zhang2025,
author = {Zhang, Mengmeng and Loeve, Arjo J and Serpe, Michael J and Bazyar, Hanieh},
title = {Etalon@lateral flow strip for integrated separation-sensing microfluidic platforms},
journal = {Biosensors and Bioelectronics},
year = {2025},
doi = {10.1016/j.bios.2025.117656}
}