Integrating microfluidic automation into thermoplastic devices for analysis of small volumes of blood
Biosensors and Bioelectronics · 2025
DOI: 10.1016/j.bios.2025.117920 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Josue U Amador-Hernandez und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Laboratory of Microtechnologies Applied to Biomedicine (LMAB), …. Hauptthemen laut MEDLINE: Microfluidic Analytical Techniques, Biosensing Techniques, Lab-On-A-Chip Devices, Blood Glucose. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: NICHD NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Microfluidic devices with built-in microvalves hold particular promise for minimizing sample volume requirements while automating sample preparation workflows. Such devices have typically been implemented in polydimethyl siloxane (PDMS) using multi-layer soft lithography. Both the material and assembly process of devices present challenges for scalable manufacturing and limit utilization of microfluidic automation at the point of care. Our work aims to address this challenge. It describes a microfluidic device composed of thermoplastic material, poly (methyl methacrylate) (PMMA) performing a sophisticated automated workflow of plasma extraction, sample aliquoting and sample-reagent mixing steps. Automation was accomplished using multiple on-board microvalves consisting of a pressure sensitive adhesive (PSA) membrane sandwiched between PMMA flow and control layers. In addition to novel microvalves, the device included features designed to circumvent issues arising from gas-impermeable nature of PMMA - a bubble trap and air micro-tanks to supply O2 for enzymatic reactions. The performance of the microfluidic device was rigorously characterized. The quality of plasma extracted in the device was comparable to a standard plasma isolation method involving centrifugation. Close agreement was observed between glucose levels measured in the device and by a standard assay. As a final demonstration of utility, 5 μL of blood was loaded into the device, plasma was isolated, and three analytes-glucose, lactate and H2O2 were detected. In addition to minimizing the volume of blood and eliminating standard laboratory equipment (e.g., centrifuge), the device enabled a rapid response (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey…
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA; Sersense Inc., Rochester, MN, USA.
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico.
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico; Institute of Human Biology, Roche Pharma Research and Early Development,…
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA. Electronic address: revzin.alexander@mayo.edu.
Förderung
- NICHD NIH HHS
- National Institutes of Health
Zitieren
APA
Amador-Hernandez, J. U., Gonzalez-Suarez, A. M., Stybayeva, G., Caballero-Robledo, G. A., Garcia-Cordero, J. L., & Revzin, A. (2025). Integrating microfluidic automation into thermoplastic devices for analysis of small volumes of blood. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.117920
Vancouver
Amador-Hernandez JU, Gonzalez-Suarez AM, Stybayeva G, Caballero-Robledo GA, Garcia-Cordero JL, Revzin A. Integrating microfluidic automation into thermoplastic devices for analysis of small volumes of blood. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2025.117920
BibTeX
@article{AmadorHernandez2025,
author = {Amador-Hernandez, Josue U and Gonzalez-Suarez, Alan M and Stybayeva, Gulnaz and Caballero-Robledo, Gabriel A and Garcia-Cordero, Jose L and Revzin, Alexander},
title = {Integrating microfluidic automation into thermoplastic devices for analysis of small volumes of blood},
journal = {Biosensors and Bioelectronics},
year = {2025},
doi = {10.1016/j.bios.2025.117920}
}
EUVIMED