EUVIMEDOpdag EUVIMED
VergleichsstudieOpen access · CC BY 4.0

An X‐ray and γ‐ray combination strategy to exploit steep dose gradients for improved prostate cancer radiotherapy: A dosimetric comparison of Taichi Pro and Halcyon

Kuo Li, Yong Yin, Ting Zhu, Weipeng Sun, Shihao Wang, Zhenjiang Li

Journal of Applied Clinical Medical Physics · 2026-03 · 27 (3)

DOI: 10.1002/acm2.70532 ↗

At a glance

Vergleichsstudie in Journal of Applied Clinical Medical Physics, published online on 2026-02-27. Written by Kuo Li and 5 co-authors. Institution: Department of Radiation Oncology Physics & Technology, Cancer Hospital of Shandong First Medical University, Jinan, China. Major MEDLINE topics: Prostatic Neoplasms, Radiotherapy Planning, Computer-Assisted, Organs at Risk, Radiotherapy, Intensity-Modulated. 30 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Natural Science Foundation of China, Collaborative Academic Innovation Project of Shandong Cancer Hospital, Taishan Scholars Program of Shandong Province.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

This study aimed to evaluate a novel technological platform, Taichi Pro—which integrates a 6 MV flattening filterfree linear accelerator with a 18 source Rotating Gamma System (RGS) to generate steep dose gradients via multisource focused γ‐rays and noncoplanar arcs—for precision radiotherapy in prostate cancer. The work provides evidence to support the clinical adoption of hybridmodality radiotherapy devices.

Methods

Fifteen prostate cancer patients were enrolled. For each patient, a dual‐modality Taichi Pro plan (RGS focused on the planning gross tumor volume (PGTV) + Linac covering the planning target volume (PTV)) and a Halcyon photon plan (three‐arc VMAT) were designed while maintaining clinically tolerable dose to organs at risk (OAR). Comparative assessments included planning target volume (PTV and PGTV) metrics (D 95% , D mean , homogeneity index HI, conformity index CI), OAR doses (rectum V 40 /V 60 /D 2cc , bladder V 40 , testis D 2cc , etc.) and delivery efficiency to evaluate the ability to escalate target dose while sparing adjacent OARs.

Results

All plans met institutional clinical constraints. Taichi Pro significantly increased PGTV D mean (79.48 Gy ± 1.75 Gy) compared to Halcyon (73.25 Gy ± 0.55 24 Gy, P < 0.001) and D max (122.74 Gy ± 8.69 Gy) compared to Halcyon (76.15 Gy ± 0.79 Gy, P < 0.001), albeit poorer homogeneity (HI: 0.50 ± 0.09 for Taichi Pro vs. 0.06 ± 0.01 for Halcyon, though within clinically acceptable limits). Taichi Pro significantly reduced rectum V 60 (3.97% ± 3.25% vs. Halcyon 7.46% ± 4.78%, P = 0.016), and D 2cc (61.61 Gy ± 5.01 Gy vs. Halcyon 65.29 Gy ± 4.52 Gy, P = 0.040). Taichi Pro also significantly reduced testis D 2cc (2.39 ± 1.99 Gy) compared to (3.17 Gy ± 1.40 Gy, P = 0.006). Halcyon demonstrated significantly shorter beam‐on time (1.81 ± 0.23 minutes vs. 5.05 ± 1.59 minutes for Taichi Pro, P < 0.001).

Conclusion

Utilizing the steep dose gradient characteristic of the RGS, the Taichi Pro dual‐modality system effectively achieved target dose escalation while simultaneously improving sparing of adjacent OARs. This approach holds the potential for enhancing patient treatment outcomes and quality of life.

Subjects

MeSH terms (MEDLINE)

Prostatic NeoplasmsRadiotherapy Planning, Computer-AssistedOrgans at RiskRadiotherapy, Intensity-ModulatedParticle AcceleratorsGamma RaysHumansMaleRadiotherapy DosageX-RaysPrognosisRadiometry

Author keywords

HalcyonTaichi Proprostate cancerrotating gamma system

Authors and institutions

  • Department of Radiation Oncology Physics & Technology, Cancer Hospital of Shandong First Medical University, Jinan, China.
  • Our United Corp, Xi'an, China.

Funding

  • National Natural Science Foundation of China
  • Collaborative Academic Innovation Project of Shandong Cancer Hospital
  • Taishan Scholars Program of Shandong Province

Cite

APA

Li, K., Yin, Y., Zhu, T., Sun, W., Wang, S., & Li, Z. (2026). An X‐ray and γ‐ray combination strategy to exploit steep dose gradients for improved prostate cancer radiotherapy: A dosimetric comparison of Taichi Pro and Halcyon. Journal of Applied Clinical Medical Physics, 27(3). https://doi.org/10.1002/acm2.70532

Vancouver

Li K, Yin Y, Zhu T, Sun W, Wang S, Li Z. An X‐ray and γ‐ray combination strategy to exploit steep dose gradients for improved prostate cancer radiotherapy: A dosimetric comparison of Taichi Pro and Halcyon. Journal of Applied Clinical Medical Physics. 2026;27(3). doi:10.1002/acm2.70532

BibTeX
@article{Li2026,
  author = {Li, Kuo and Yin, Yong and Zhu, Ting and Sun, Weipeng and Wang, Shihao and Li, Zhenjiang},
  title = {An X‐ray and γ‐ray combination strategy to exploit steep dose gradients for improved prostate cancer radiotherapy: A dosimetric comparison of Taichi Pro and Halcyon},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  volume = {27},
  number = {3},
  doi = {10.1002/acm2.70532}
}
Start for free →