Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Maggie Yan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Information and Science Engineering, University of Florida, Gainesville, Florida, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Organs at Risk, Prostatic Neoplasms, Pancreatic Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The unique design of the MR‐linac may restrict the use of effective immobilization devices, resulting in significant patient setup variations (PSVs). The purpose of this study is to analyze the PSVs on the Elekta Unity system and investigate their impact on adaptive planning.
Methods
The PSVs for 10 brain, 10 pancreas, five prostate, and five rectum patients previously treated on Elekta Unity were analyzed. The five prostate and five pancreas plans were selected to investigate the impact of PSVs on adaptive planning. The reference scans were shifted by 1, 2, and 3 cm in the left–right (LR) and superior–inferior (SI) directions to simulate PSVs. Both the adaptive‐to‐position (ATP) and adaptive‐to‐shape (ATS) workflows were executed. The adaptive planning time, number of monitor units (MUs), and dosimetric metrics quantifying target coverage and organ‐at‐risks (OARs) sparing were compared.
Results
For brain treatments, the average/maximum PSVs were −0.2 ± 0.3 cm/0.8 cm (LR), 0.3 ± 0.7 cm/1.8 cm (SI), and 0.8 ± 0.7 cm/1.8 cm in the anterior–posterior (AP) direction. For pancreas treatments, the PSVs are −0.1 ± 1.0 cm/3.8 cm (LR), −0.1 ± 0.8 cm/3.5 cm (SI), and 0.3 ± 0.3 cm/1.3 cm (AP). Pelvis treatments had similar PSVs as pancreas treatments. The ATS workflow took two to three times longer than the ATP workflow. The only trend observed was that the plan MUs increased slightly (< 10%) with PSVs in the ATP workflow for prostate patients. Both workflows effectively reproduced target coverage and OAR sparing, regardless of the magnitude of the PSVs.
Conclusions
Significant PSVs were observed on Elekta Unity due to suboptimal patient immobilization. Using prostate and pancreas treatments as examples, we demonstrated that adaptive planning can effectively accommodate such PSVs. Nevertheless, efforts should be made to minimize PSVs—particularly rotations—to mitigate intra‐fraction motion and reduce treatment time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Computer Information and Science Engineering, University of Florida, Gainesville, Florida, USA.
- Department of Radiation Oncology, University of Florida, Gainesville, Florida, USA.
Zitieren
APA
Yan, M., Kollitz, E., Sun, S. H., Hitchcock, K., De Leo, A., Schwarz, A., Maloney, L., Li, J., Liu, C., & Yan, G. (2025). Patient setup variation on Elekta Unity and its impact on adaptive planning. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70016
Vancouver
Yan M, Kollitz E, Sun SH, Hitchcock K, De Leo A, Schwarz A, et al. Patient setup variation on Elekta Unity and its impact on adaptive planning. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70016
BibTeX
@article{Yan2025,
author = {Yan, Maggie and Kollitz, Erika and Sun, Sheng-Hsuan and Hitchcock, Kathryn and De Leo, Alexandra and Schwarz, Amanda and Maloney, Luke and Li, Jonathan and Liu, Chihray and Yan, Guanghua},
title = {Patient setup variation on Elekta Unity and its impact on adaptive planning},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70016}
}
EUVIMED