EUVIMEDEUVIMED entdecken
Multizentrische StudieEvaluationsstudieOpen Access · CC BY 4.0

Evaluating consistency of radiomic features derived from CT images: A cross‐center phantom study

Lorna Tu iD, Hervé H F Choi iD, Haley Clark iD, Bradford Gill, Scott Young, Samantha A M Lloyd iD

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70482 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Lorna Tu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada. Hauptthemen laut MEDLINE: Lung Neoplasms, Phantoms, Imaging, Radiomics, Tomography, X-Ray Computed. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, BC Cancer Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the consistency of radiomic features extracted from computed tomography (CT) scans across CT radiotherapy simulators geographically spread across a Canadian province using a simplified lung radiomic phantom, and to determine whether it is appropriate to combine multicenter imaging data into a single dataset.

Methods

An inexpensive phantom was created using foam with a density similar to lung and a plastic vial insert filled with water. It was imaged at six provincial radiotherapy treatment centers using eight GE CT radiotherapy simulators and routine lung stereotactic ablative radiotherapy planning CT acquisition protocols. Radiomic features were extracted from regions of interest using Imaging Biomarker Explorer radiomics software and compared using Kruskal Wallis H tests, intraclass correlation coefficient (ICC), and coefficient of variation (CV).

Results

Image acquisition parameters were similar across centers. At the population level, no significant inconsistencies between radiomic features originating from different centers or from within the same center were observed (Bonferroni‐corrected p > 0.05; ICC > 0.941). On average, 52.5% of features were considered consistent (CV ≤ 0.10).

Conclusions

The proposed phantom was transported across widespread centers without detectable damage and demonstrates potential for easy quality assurance checks on radiomic feature consistency within a multi‐institutional setting. Our analysis suggests that some features should be omitted or standardized before combining provincial imaging data into a harmonized lung radiotherapy dataset. These preliminary findings lay the groundwork for further investigation into provincial radiomic feature consistency and potential application to multicenter clinical studies. Owing to potential differences in imaging protocols, a consistency evaluation should be performed before undertaking radiomic analysis of data combined from different institutions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lung NeoplasmsPhantoms, ImagingRadiomicsTomography, X-Ray ComputedHumansImage Processing, Computer-AssistedRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-Modulated

Stichwörter der Autor:innen

computed tomographyfeature consistencymulti‐institutionalphantomradiomics

Autor:innen und Institutionen

  • Department of Physics and Astronomy, University of British Columbia, Vancouver, British Columbia, Canada.
  • Department of Medical Physics, BC Cancer, Vancouver, British Columbia, Canada.
  • Department of Medical Physics, BC Cancer, Surrey, British Columbia, Canada.

ORCID-Profile: Lorna Tu, Hervé H F Choi, Haley Clark, Samantha A M Lloyd

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • BC Cancer Foundation

Zitieren

APA

Tu, L., Choi, H. H. F., Clark, H., Gill, B., Young, S., & Lloyd, S. A. M. (2026). Evaluating consistency of radiomic features derived from CT images: A cross‐center phantom study. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70482

Vancouver

Tu L, Choi HHF, Clark H, Gill B, Young S, Lloyd SAM. Evaluating consistency of radiomic features derived from CT images: A cross‐center phantom study. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70482

BibTeX
@article{Tu2026,
  author = {Tu, Lorna and Choi, Hervé H F and Clark, Haley and Gill, Bradford and Young, Scott and Lloyd, Samantha A M},
  title = {Evaluating consistency of radiomic features derived from CT images: A cross‐center phantom study},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70482}
}
Kostenlos starten →