Commissioning of a gantry‐mounted synchrocyclotron for preclinical FLASH studies utilizing spread‐out Bragg peaks
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70357 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Michael Lowe und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, WashU Medicine, St. Louis, Missouri, USA. Hauptthemen laut MEDLINE: Proton Therapy, Particle Accelerators, Radiotherapy Planning, Computer-Assisted, Phantoms, Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIH HHS, National Cancer Institute.
Abstract (Originalsprache)
Background
Preclinical studies demonstrate the benefits of ultra‐high dose‐rate (FLASH) radiation, reducing normal tissue toxicity while maintaining tumoricidal effects. Proton FLASH (pFLASH) studies typically use transmission beams, missing the normal tissue‐sparing advantage of the spread‐out Bragg peak (SOBP).
Purpose
This study aims to propose and implement a series of modifications to enable a clinical Mevion S250i gantry‐mounted synchrocyclotron to deliver pFLASH within the SOBP of the proton beam.
Methods
A clinical synchrocyclotron was modified to enable FLASH proton beam delivery using the Mevion FLASH accessory kit, a commercially available tool that allows for the delivery of a single spot SOBP at FLASH dose rates. To ensure accurate beam monitoring, a Faraday cup was utilized to measure the integral charge per delivery at different dose rates and calibrate the FLASH transmission ion chamber (FLASHTic), which is integrated in the FLASH accessory mount attached to the nozzle of the gantry. The FLASHTic was specifically designed to prevent saturation at the dose rates associated with FLASH. To generate the desired single spot SOBP, boron carbide absorbers, a range modulating hole filter, and an 11‐mm‐diameter circle brass aperture were employed on the FLASH nozzle mount.
Results
The results indicate that the FLASHTic measurements demonstrated a strong correlation with the Faraday cup post calibration, suggesting that the FLASHTic can be effectively utilized for both monitoring and terminating the proton beam. The 80%–80% width of the SOBP was 2.01 cm. The peak dose rate at the SOBP proximal peak reached 105.03 Gy/s, with an average of 96.18 Gy/s over five days. Transitioning between FLASH and clinical mode required less than one hour without affecting the clinical beam.
Conclusions
The commissioning of a 230 MeV proton synchrocyclotron for SOBP FLASH delivery was achieved, providing a platform for preclinical small animal studies on pFLASH effects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, WashU Medicine, St. Louis, Missouri, USA.
- Department of Advanced Development, Mevion Medical Systems, Littleton, Massachusetts, USA.
ORCID-Profile: Arash Darafsheh
Förderung
- NCI NIH HHS
- NIH HHS
- National Cancer Institute
- National Institutes of Health
Zitieren
APA
Lowe, M., Zhang, H., Owen, D., Darafsheh, A., & Zhao, T. (2025). Commissioning of a gantry‐mounted synchrocyclotron for preclinical FLASH studies utilizing spread‐out Bragg peaks. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70357
Vancouver
Lowe M, Zhang H, Owen D, Darafsheh A, Zhao T. Commissioning of a gantry‐mounted synchrocyclotron for preclinical FLASH studies utilizing spread‐out Bragg peaks. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70357
BibTeX
@article{Lowe2025,
author = {Lowe, Michael and Zhang, Hailei and Owen, Daniel and Darafsheh, Arash and Zhao, Tianyu},
title = {Commissioning of a gantry‐mounted synchrocyclotron for preclinical FLASH studies utilizing spread‐out Bragg peaks},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70357}
}
EUVIMED