Impact of respiratory motion on dose distribution in SIB‐SBRT for lung cancer
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70136 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Lingling Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: University of Science and Technology of China, Hefei, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Lung Neoplasms, Radiotherapy, Intensity-Modulated, Four-Dimensional Computed Tomography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation of China, Nature Science Research Project of Anhui Province, Health Research Program of Anhui.
Abstract (Originalsprache)
Purpose
Respiratory motion is a major source of dose uncertainty in lung cancer radiotherapy. The dose distribution of simultaneous integrated boost‐stereotactic body radiotherapy (SIB‐SBRT) is inhomogeneous and is significantly impacted by respiratory motion for lung cancer. The effect of respiratory motion on SIB‐SBRT was investigated with a four‐dimensional (4D) dose calculation method.
Methods
Nineteen previously treated lung cancer patients were selected for this planning study. All patients underwent four‐dimensional CT (4D‐CT) scanning, and volumetric modulated arc therapy (VMAT) treatments were planned with internal target volume (ITV) and planning target volume (PTV). Dose distributions (3D‐plan) were calculated on the average reconstruction of the 4D‐CT. 4D dose distributions (4D‐plan) were calculated to evaluate respiratory motion effects. These calculations were performed on the CT images of related respiratory phase with a respiration‐correlated assignment of the 3D plan's monitor units to the respiratory phases of the 4D‐CT. Subsequently, the accumulative 4D dose based on deformable registrations of the CT series was generated and compared to the 3D dose distribution. Dosimetric deviations in targets and organs at risk (OARs) were analyzed with dosimetric parameters, and correlations between dose deviations (Δ V 100 (ITV, PTV)) and patient characteristics (left–right, SI, anterior–posterior, S, L, Volume (ITV, PTV)) were explored.
Results
With deformable registrations, the median values of relative differences between 3D‐plan and 4D‐plan 0 were found to be from −6.6% to 12.1% for all targets dosimetric parameters, and from −4.2% to 1.4% for OAR parameters. It was also shown that PTV coverage dropped more significantly than that of ITV with respiratory motion. Strong correlations were observed between the Δ V 100 (ITV, PTV) and patient characteristic (SI, S, L).
Conclusion
Respiratory motion effects during SIB‐SBRT treatment resulted in non‐negligible dose variability. Furthermore, with the correlation relationship and respiratory motion parameters, the dose coverage reduction of targets could be predicted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Science and Technology of China, Hefei, China.
- Hefei Cancer Hospital of CAS, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.
- Department of Oncology, The 901st Hospital of Joint Logistics Support Force of the Chinese People's Liberation Army, Hefei, China.
- Department of Oncology, Zibo Wanjie Hospital, Zibo, China.
Förderung
- National Science Foundation of China
- Nature Science Research Project of Anhui Province
- Health Research Program of Anhui
- National Natural Science Foundation of China
Zitieren
APA
Liu, L., Fei, Z., Li, J., Shu, J., Shao, J., Zhang, J., Cui, X., & Wang, H. (2025). Impact of respiratory motion on dose distribution in SIB‐SBRT for lung cancer. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70136
Vancouver
Liu L, Fei Z, Li J, Shu J, Shao J, Zhang J, et al. Impact of respiratory motion on dose distribution in SIB‐SBRT for lung cancer. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70136
BibTeX
@article{Liu2025,
author = {Liu, Lingling and Fei, Zhenle and Li, Jie and Shu, Jiong and Shao, Jingyuan and Zhang, Jianguang and Cui, Xiangli and Wang, Hongzhi},
title = {Impact of respiratory motion on dose distribution in SIB‐SBRT for lung cancer},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70136}
}
EUVIMED