Impact of abdominal compression on heart and stomach motion for stereotactic arrhythmia radioablation
Journal of Applied Clinical Medical Physics · 2024
DOI: 10.1002/acm2.14346 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Daniel David Cecchi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy Planning, Computer-Assisted, Four-Dimensional Computed Tomography, Respiration. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To evaluate the effectiveness of abdominal compression (AC) as a respiratory motion management method for the heart and stomach during stereotactic arrhythmia radioablation (STAR).
Methods
4D computed tomography (4DCT) scans of patients imaged with AC or without AC (free‐breathing: FB) were obtained from ventricular‐tachycardia (VT) ( n = 3), lung cancer ( n = 18), and liver cancer ( n = 18) patients. Patients treated for VT were imaged both FB and with AC. Lung and liver patients were imaged once with FB or with AC, respectively. The heart, left ventricle (LV), LV components (LVCs), and stomach were contoured on each phase of the 4DCTs. Centre of mass (COM) translations in the left/right (LR), ant/post (AP), and sup/inf (SI) directions were measured for each structure. Minimum distances between LVCs and the stomach over the respiratory cycle were also measured on each 4DCT phase. Mann‐Whitney U‐tests were performed between AC and FB datasets with a significance of α = 0.05.
Results
No statistical difference (all p values were >0.05) was found in COM translations between FB and AC patient datasets for all contoured cardiac structures. A reduction in COM translation with AC relative to FB was patient, direction, and structure specific for the three VT patients. A significant decrease in the AP range of motion of the stomach was observed under AC compared to FB. No statistical difference was found between minimum distances to the stomach and LVCs between FB and AC.
Conclusions
AC was not a consistent motion management method for STAR, nor does not uniformly affect the separation distance between LVCs and the stomach. If AC is employed in future STAR protocols, the motion of the target volume and its relative distance to the stomach should be compared on two 4DCTs: one while the patient is FB and one under AC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada.
- Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada.
- Department of Oncology, Division of Medical Physics, University of Calgary, Calgary, Alberta, Canada.
- Department of Radiation Oncology, Tom Baker Cancer Centre, Calgary, Alberta, Canada.
- Department of Oncology, Division of Radiation Oncology, University of Calgary, Calgary, Alberta, Canada.
Zitieren
APA
Cecchi, D. D., Ploquin, N. P., Faruqi, S., & Morrison, H. (2024). Impact of abdominal compression on heart and stomach motion for stereotactic arrhythmia radioablation. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14346
Vancouver
Cecchi DD, Ploquin NP, Faruqi S, Morrison H. Impact of abdominal compression on heart and stomach motion for stereotactic arrhythmia radioablation. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14346
BibTeX
@article{Cecchi2024,
author = {Cecchi, Daniel David and Ploquin, Nicolas Paul and Faruqi, Salman and Morrison, Hali},
title = {Impact of abdominal compression on heart and stomach motion for stereotactic arrhythmia radioablation},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14346}
}
EUVIMED