Optimizing cardio‐respiratory motion management in stereotactic arrhythmia radioablation through mid‐position planning target volume
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70170 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Adèle Gabillaud und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, CLCC Eugène Marquis, Rennes, France. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiosurgery, Arrhythmias, Cardiac, Tachycardia, Ventricular. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: French National Research Association (ANR), Fédération Française de Cardiologie, through the RADAR-CINETIC project.
Abstract (Originalsprache)
Purpose/objective This study proposes an implementation of the mid‐position (MidP) approach to compensate for cardio‐respiratory motions in the context of Stereotactic Arrhythmia Radioablation (STAR) and evaluates its benefits compared to an internal target volume (ITV) approach. Materials and methods Fifteen patients who underwent STAR for refractory ventricular tachycardia in our institution were included in this retrospective planning study. For each patient, a cardiac‐gated four‐dimensional computed tomography (4D‐CT card ) scan and a respiratory‐gated four‐dimensional computed tomography (4D‐CT resp) were acquired. All patients were treated using a volumetric modulated arc therapy technique using an in‐treatment Cone‐Beam CT (CBCT) image guidance. The MidP approach was implemented to compensate for uncertainties, including cardio‐respiratory motions characterized using the 4D‐CT card and 4D‐CT resp scans, and the inter‐fraction motions measured using the CBCT scans. For comparison purposes, the ITV approach was also implemented. Both approaches were compared in terms of planning target volume (PTV) volumes, doses to organs‐at‐risk, and clinical target volume (CTV) doses, assessed using a 4D modeling method that estimates the accumulated dose.
Results
Compared with the ITV method, the MidP approach resulted in a mean [min‐max] relative PTV volume reduction of 30% [19%, 48%] ( p < 0.001, Wilcoxon signed rank test). The mean [min‐max] D95% CTV coverage was 105% [101%–114%] and 107% [101%–117%] of the prescription dose for MidP and ITV‐based plans, respectively. The median dose to the whole heart was significantly lower with MidP‐based plans with a mean difference of −0.5 Gy ( p = 0.0084). The near‐maximum dose (D1%) delivered to left coronary arteries, aorta, and stomach was systematically lower with the MidP‐based plans.
Conclusion
Compared to ITV based approach, the use of MidP strategy for treatment planning of STAR leads to significantly smaller PTV and lower surrounding OAR doses while still achieving a clinically acceptable CTV coverage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics, CLCC Eugène Marquis, Rennes, France.
- Univ Rennes, CHU Rennes, CLCC Eugène Marquis, Inserm, Rennes, France.
- Department of Radiation Oncology, CLCC Eugène Marquis, Rennes, France.
- Department of Cardiology, Saint-Etienne University Hospital, Saint-Priest-En-Jarez, France.
Förderung
- French National Research Association (ANR)
- Fédération Française de Cardiologie, through the RADAR-CINETIC project
Zitieren
APA
Gabillaud, A., Rigal, L., Martins, R., De Crevoisier, R., Cisneros, J., Duvergé, L., Lederlin, M., Delaby, N., Benali, K., Simon, A., & Bellec, J. (2025). Optimizing cardio‐respiratory motion management in stereotactic arrhythmia radioablation through mid‐position planning target volume. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70170
Vancouver
Gabillaud A, Rigal L, Martins R, De Crevoisier R, Cisneros J, Duvergé L, et al. Optimizing cardio‐respiratory motion management in stereotactic arrhythmia radioablation through mid‐position planning target volume. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70170
BibTeX
@article{Gabillaud2025,
author = {Gabillaud, Adèle and Rigal, Louis and Martins, Raphaël and De Crevoisier, Renaud and Cisneros, Juan and Duvergé, Loïg and Lederlin, Mathieu and Delaby, Nolwenn and Benali, Karim and Simon, Antoine and Bellec, Julien},
title = {Optimizing cardio‐respiratory motion management in stereotactic arrhythmia radioablation through mid‐position planning target volume},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70170}
}
EUVIMED