DICOM attribute manipulation tool: Easily change frame of reference, series instance, and SOP instance UID
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70104 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Brian M Anderson und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of North Carolina, Chapel Hill, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Software, Image Processing, Computer-Assisted, Magnetic Resonance Imaging. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose In radiation oncology, the integration and registration of multiple imaging modalities is a crucial aspect of the diagnosis and treatment planning process. These images are often inherently registered, a useful feature in most cases, but possibly a hindrance when registration modifications are required. To break this registration requires expert knowledge of file structure or specialized software, posing challenges, and potential errors in accidentally or unnecessarily changing other attributes. Barring these changes, the clinic would have to make do with imprecise registrations which compound overall treatment uncertainty. To address these issues, we present a novel tool designed to simplify the task of changing three often edited attributes: the frame of reference, the series instance unique identifier (UID), and the SOP instance UID. The tool features an intuitive user interface that empowers practitioners, regardless of their expertise, to effortlessly modify these three commonly edited values. Validation methods Publicly available brain MRI and TCI lung 4DCT images were used to evaluate the software. The ability to change the frame of reference, series instance identifier, and SOP instance identifier using the program was evaluated with both the RayStation treatment planning system and MIM. Software format and usage notes The program is written in C#, easily distributed via GitHub and is compatible with any Windows computer with .NET 4.8 (the standard as of 2023). Potential applications This innovation holds promise for improving the overall workflow efficiency and safety within radiation oncology and radiology, where breaking the frame of reference or changing the series/SOP UIDs is a common occurrence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, University of North Carolina, Chapel Hill, USA.
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California, USA.
ORCID-Profile: Brian M Anderson
Zitieren
APA
Anderson, B. M., & Bojechko, C. (2025). DICOM attribute manipulation tool: Easily change frame of reference, series instance, and SOP instance UID. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70104
Vancouver
Anderson BM, Bojechko C. DICOM attribute manipulation tool: Easily change frame of reference, series instance, and SOP instance UID. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70104
BibTeX
@article{Anderson2025,
author = {Anderson, Brian M and Bojechko, Casey},
title = {DICOM attribute manipulation tool: Easily change frame of reference, series instance, and SOP instance UID},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70104}
}
EUVIMED