EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Patient Positional Uncertainty and Margin Reduction in Lung Stereotactic Ablative Radiation Therapy Using Pneumatic Abdominal Compression

Yohan A Walter, Chiachien J Wang, Daniel B Speir, William E Burrell, Carlos D Palomeque, James C Henry, Megan M Rodrigues, Troy D Jacobs, Bethany L Broekhoven, Joseph P Dugas, Anne N Hubbard, Philip F Durham und 1 weitere

Practical Radiation Oncology · 2025

DOI: 10.1016/j.prro.2024.12.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Practical Radiation Oncology, 2025. Verfasst von Yohan A Walter und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Research, University of Jamestown, Fargo, North Dakota; Department of Radiation Oncology, Willis Knighton Cancer Center, Shrev…. Hauptthemen laut MEDLINE: Radiosurgery, Lung Neoplasms, Patient Positioning, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Motion management presents a significant challenge in thoracic stereotactic ablative radiation therapy (SABR). Currently, a 5.0-mm standard planning target volume (PTV) margin is widely used to ensure adequate dose to the tumor. Considering recent advancements in tumor localization and motion management, there is merit to reassessing the necessary PTV margins for modern techniques. This work presents a large-scale analysis of intrafraction repositioning for lung SABR under forced shallow breathing to determine the margin requirements for modern delivery techniques. METHODS AND MATERIALS: Treatment data for 124 lung SABR patients treated in 607 fractions on a linear accelerator were retrospectively collected for analysis. All patients were treated using pneumatic abdominal compression and intrafraction 4-dimensional (4D) cone beam computed tomography (4D CBCT)-guided repositioning halfway through treatment. Executed repositioning shifts were collected and used to calculate margin requirements using the 2-SD method and an analytical model which accounts for systematic and random errors in treatment. RESULTS: A total of 85.7% of treated fractions had 3-dimensional repositioning shifts under 5.0 mm. Fifty-three fractions (8.7%) had shifts ≥ 5.0 mm in at least 1 direction. Margins in the right-left, inferior-superior, and posterior-anterior directions were 3.62 mm, 4.34 mm, and 3.50 mm, respectively, calculated using the 2-SD method. The analytical approach estimated that 4.01 mm, 4.37 mm, and 3.95 mm margins were appropriate for our workflow. Executing intrafraction repositioning reduced margin requirements by 0.73 ± 0.07 mm. CONCLUSIONS: Clinical data suggest that the uniform 5.0-mm margin is conservative for our workflow. Using modern techniques such as 4D CT, 4D CBCT, and effective motion management can significantly reduce required margins, and therefore necessary healthy tissue dose. However, the limitations of margin calculation models must be considered, and margin reduction must be approached with caution. Users should conduct a formal risk assessment prior to adopting new standard PTV margins.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryLung NeoplasmsPatient PositioningRadiotherapy Planning, Computer-AssistedHumansRetrospective StudiesCone-Beam Computed TomographyUncertaintyMaleFour-Dimensional Computed TomographyFemale

Autor:innen und Institutionen

  • Department of Clinical Research, University of Jamestown, Fargo, North Dakota; Department of Radiation Oncology, Willis Knighton Cancer Center, Shreveport, Louisiana. Electronic address: ywalter@wkhs.com.
  • Department of Radiation Oncology, Willis Knighton Cancer Center, Shreveport, Louisiana.

Zitieren

APA

Walter, Y. A., Wang, C. J., Speir, D. B., Burrell, W. E., Palomeque, C. D., Henry, J. C., Rodrigues, M. M., Jacobs, T. D., Broekhoven, B. L., Dugas, J. P., Hubbard, A. N., Durham, P. F., & Wu, H. T. (2025). Patient Positional Uncertainty and Margin Reduction in Lung Stereotactic Ablative Radiation Therapy Using Pneumatic Abdominal Compression. Practical Radiation Oncology. https://doi.org/10.1016/j.prro.2024.12.001

Vancouver

Walter YA, Wang CJ, Speir DB, Burrell WE, Palomeque CD, Henry JC, et al. Patient Positional Uncertainty and Margin Reduction in Lung Stereotactic Ablative Radiation Therapy Using Pneumatic Abdominal Compression. Practical Radiation Oncology. 2025. doi:10.1016/j.prro.2024.12.001

BibTeX
@article{Walter2025,
  author = {Walter, Yohan A and Wang, Chiachien J and Speir, Daniel B and Burrell, William E and Palomeque, Carlos D and Henry, James C and Rodrigues, Megan M and Jacobs, Troy D and Broekhoven, Bethany L and Dugas, Joseph P and Hubbard, Anne N and Durham, Philip F and Wu, Hsinshun T},
  title = {Patient Positional Uncertainty and Margin Reduction in Lung Stereotactic Ablative Radiation Therapy Using Pneumatic Abdominal Compression},
  journal = {Practical Radiation Oncology},
  year = {2025},
  doi = {10.1016/j.prro.2024.12.001}
}
Kostenlos starten →