EUVIMEDEUVIMED entdecken
Crossref

Glandular Dose of Full Field Digital Mammography in Korean Women Based on Specific Factors

Seung Hee Han, Bong Joo Kang, Ji Eun Baek, Hyun Sil Lee, Sung Hun Kim

Iranian Journal of Radiology · 01.08.2018 · In Press (In Press)

DOI: 10.5812/iranjradiol.62958 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Iranian Journal of Radiology, online erschienen am 01.08.2018. Verfasst von Seung Hee Han und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mammographic screening for breast cancer has been proved to reduce mortality. However, because of the potential harm of ionizing radiation, radiation dose management has been issued.

Objectives

We investigated the influence of several factors on the radiation dose change in full-field digital mammography (FFDM) using a radiation dose management system in Korean women. Patients and Methods: Using an existing radiation dose management system (RadimetricsTM), radiation dose tracking, monitoring, and statistical analyses were conducted. Information including parameters, utilization data, and a dose report were sent to the conventional picture archiving, communication system, and radiation dose management system. We reviewed the data and compared the parameters (exposure, glandular dose, compression thickness, and compression force) between two different devices, among classifications (plain, spot and magnification view, and implant), and between control modes (auto and manual). An association between compression thickness and glandular dose was evaluated. Finally, the glandular dose differences based on age, device, classification, control mode, exposure, compression thickness, and compression force were additionally investigated.

Results

From February 25th to June 30th, 2015, a total of 15665 mammogram images of 3958 patients were performed and sent to the conventional picture archiving and communication system (PACS) and the radiation dose management system. A significant difference was observed in glandular dose, compression thickness, compression force, and exposure depending on the type of device (P

Zitieren

APA

Han, S. H., Kang, B. J., Baek, J. E., Lee, H. S., & Kim, S. H. (2018). Glandular Dose of Full Field Digital Mammography in Korean Women Based on Specific Factors. Iranian Journal of Radiology, In Press(In Press). https://doi.org/10.5812/iranjradiol.62958

Vancouver

Han SH, Kang BJ, Baek JE, Lee HS, Kim SH. Glandular Dose of Full Field Digital Mammography in Korean Women Based on Specific Factors. Iranian Journal of Radiology. 2018;In Press(In Press). doi:10.5812/iranjradiol.62958

BibTeX
@article{Han2018,
  author = {Han, Seung Hee and Kang, Bong Joo and Baek, Ji Eun and Lee, Hyun Sil and Kim, Sung Hun},
  title = {Glandular Dose of Full Field Digital Mammography in Korean Women Based on Specific Factors},
  journal = {Iranian Journal of Radiology},
  year = {2018},
  volume = {In Press},
  number = {In Press},
  doi = {10.5812/iranjradiol.62958}
}
Kostenlos starten →