EUVIMEDObjevte EUVIMED
Open access · CC BY-NC 4.0

Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease

Chul Kim, Jun Hyeong Song, Seung Hyoun Kim

Annals of Rehabilitation Medicine · 2023-08-31 · 47 (4) · 261-271

DOI: 10.5535/arm.23019 ↗

At a glance

Journal article in Annals of Rehabilitation Medicine, published on 2023-08-31. Written by Chul Kim and 2 co-authors. Institution: Department of Rehabilitation Medicine, Inje University Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea. Cited 30 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY-NC 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Objective

To assess the accuracy of recently commercialized wearable devices in heart rate (HR) measurement during cardiopulmonary exercise test (CPX) under gradual increase in exercise intensity, while wearable devices with HR monitors are reported to be less accurate in different exercise intensities.

Methods

CPX was performed for patients with coronary artery disease (CAD). Twelve lead electrocardiograph (ECG) was the gold standard and Apple watch 7 (AW7), Galaxy watch 4 (GW4) and Bio Patch Mobicare 200 (MC200) were applied for comparison. Paired absolute difference (PAD), mean absolute percentage error (MAPE) and intraclass correlation coefficient (ICC) were evaluated for each device.

Results

Forty-four participants with CAD were included. All the devices showed MAPE under 2% and ICC above 0.9 in rest, exercise and recovery phases (MC200=0.999, GW4=0.997, AW7=0.998). When comparing exercise and recovery phase, PAD of MC200 and AW7 in recovery phase were significantly bigger than PAD of exercise phase (p

Subjects

Author keywords

Cardiac rehabilitationExercise testHeart rateWearable electronic devices

Authors and institutions

  • Department of Rehabilitation Medicine, Inje University Sanggye Paik Hospital, Inje University College of Medicine, Seoul, Korea.

Cite

APA

Kim, C., Song, J. H., & Kim, S. H. (2023). Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease. Annals of Rehabilitation Medicine, 47(4), 261-271. https://doi.org/10.5535/arm.23019

Vancouver

Kim C, Song JH, Kim SH. Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease. Annals of Rehabilitation Medicine. 2023;47(4):261-271. doi:10.5535/arm.23019

BibTeX
@article{Kim2023,
  author = {Kim, Chul and Song, Jun Hyeong and Kim, Seung Hyoun},
  title = {Validation of Wearable Digital Devices for Heart Rate Measurement During Exercise Test in Patients With Coronary Artery Disease},
  journal = {Annals of Rehabilitation Medicine},
  year = {2023},
  volume = {47},
  number = {4},
  pages = {261--271},
  doi = {10.5535/arm.23019}
}
Start for free →